Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications
56 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 90: Event Codes (continued)
# Event Type Zone
Open/Close:
464
Auto Arm Time
Extended
Status-Auto Arm Time Ext.-
User # (Restore not
applicable)
465 Panic Alarm Reset
Status-PA Reset (Restore not
applicable)
Remote Access:
411
Callback
Requested
Remote-Callback Requested
(Restore not applicable)
412
Success-
Download/access
Remote-Successful Access
(Restore not applicable)
413
Unsuccessful
Access
Remote-Unsuccessful Access
(Restore not applicable)
414 System Shutdown Remote-System Shutdown
415 Dialer Shutdown Remote-Dialer Shutdown
416 Successful Upload
Remote-Successful Upload
(Restore not applicable)
Access Control:
421 Access Denied
Access-Access Denied-User
# (Restore not applicable)
422
Access Report by
User
Access-Access Gained-User
# (Restore not applicable)
423 Forced Access Panic-Forced Access-#
424 Egress Denied
Access-Egress Denied
(Restore not applicable)
425 Egress Granted
Access-Egress Granted
(Restore not applicable)
426
Access Door
Propped Open
Access-Door Propped Open-
#
427
Access Point DSM
Trouble
Access-ACS Point DSM Trbl.-
#
428
Access Point RTE
Trouble
Access-ACS Point RTE Trbl.-
#
429
Access Program
Mode Entry
Access-ACS Prog. Entry-User
# (Restore not applicable)
430
Access Program
Mode Exit
Access-ACS Prog. Exit-User
# (Restore not applicable)
431
Access Threat
Level Change
Access-ACS Threat Level
Chg.
432
Access
Relay/Trigger Fail
Access-ACS Relay/Trig. Fail-
#
433 Access RTE Shunt Access-ACS RTE Shunt-#
434 Access DSM Shunt Access-ACS DSM Shunt-#
System Disables:
501
Access Reader
Disable
Disable-Access Rdr. Disable-
#
Table 90: Event Codes (continued)
# Event Type Zone
Sounder/Relay Disables:
520
Sounder/Relay
Disable
Disable-Sounder/Relay-#
521 Bell 1 Disable Disable-Bell/Siren #1
522 Bell 2 Disable Disable-Bell/Siren #2
523
Alarm Relay
Disable
Disable-Alarm Relay
524
Trouble Relay
Disable
Disable-Trouble Relay
525
Reversing Relay
Disable
Disable-Reversing Relay
526
Notification
Appliance Ckt #3
Disable-Notification Appl. Ckt
#3
527
Notification
Appliance Ckt #4
Disable-Notification Appl. Ckt
#4
System Peripheral Disables:
531 Module Added
Super.-Module Added
(Restore not applicable)
532 Module Removed
Super.-Module Removed
(Restore not applicable)
Communication Disables:
551 Dialer Disabled Disable-Dialer Disable
552
Radio Xmitter
Disabled
Disable-Radio Disable
553
Remote
Upload/Download
Disable-Rem. Up/Download
Disable
Bypasses:
570
Zone/Sensor
Bypass
Bypass-Zone Bypass-#
571 Fire Bypass Bypass-Fire Bypass-#
572
24 Hour Zone
Bypass
Bypass-24 Hour Bypass-#
573 Burg. Bypass Bypass-Burg. Bypass-#
574 Group Bypass Bypass-Group Bypass-User #
575 Swinger Bypass Bypass-Swinger Bypass-#
576 Access Zone Shunt Access-ACS Zone Shunt-#
577
Access Point
Bypass
Access-ACS Point Bypass-#