5-119
FAX-L1000 Chapter 5: Appendix
ISDN BASIC Bitswitch SW06
Bit Function 1 0
0 Sending Complete information Add Don’t Add
element
1 Not used
2 Not used
3 Not used
4 Not used
5 Not used
6 LLC information element Don’t Add Add
7 HLC information element Don’t Add Add
[Bit 0]
For all outgoing calls, the Sending Complete information element in the SETUP message
can be set to “Add” or “Don't Add.” If the Sending Complete information element is not
added to the SETUP message, the SETUP message may not be received, depending on the
switching equipment. In such cases, set to “Add.”
[Bit 6]
For all outgoing calls, the LL (Low Layer Compatibility) information element in the
SETUP message can be set to “Add” or “Don't Add.”
If “Don’t Add” is set, ISDN BASIC Bitswitch SW03 Bit4, SW03 Bit5, and SW13 Bit0
settings under the #4C ISDN BASIC menu are unavailable.
[Bit 7]
For all outgoing calls, the HLC (High Layer Compatibility) information element in the
SETUP message can be set to “Add” or “Don't Add.”
If “Don’t Add” is set, ISDN BASIC Bitswitch SW03 Bit2, SW08 Bit2, and SW13 Bit1
settings under the #4C ISDN BASIC menu are unavailable
ISDN BASIC Bitswitch SW07
Bit Function 1 0
0 Not used
1 Not used
2 Not used
3 Not used
4 D-channel communications log Save Don’t Save
5 Not used
6 Not used
7 Not used
[Bit 4]
It is possible to select whether or not to log D-channel communications. To output a D-
channel dump list, set to “Save.”