Cino MP3200 Printer User Manual


 
Command Descriptions
Programming Reference
VERSAJET MP3200
GS C 2
[Name] Select the serial number counter value
[Format] ASCII GS C 2 nL nH
Hex 1D 43 32 nL nH
Decimal 29 67 50 nL nH
[Range] 0 (nL + nH x 256) 65535 (0 nL 255, 0 nH 255)
[Default] (nL + nH x 256) = 1 (nL = 1, nH = 0)
[Description] Sets the serial number counter value. Specifies the counter value as ( nL + nH xҏ 256).
[Notes] Settings of this command are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
110 Preliminary Rev. 02