Command Descriptions
Programming Reference
VERSAJET MP3200
ESC &
[Name] Define user-defined characters
[Format] ASCII ESC & y c1 c2 [x1 d1 d(yx x1)] [xk d1 d(yx xk)]
Hex 1B 26 y c1 c2 [x1 d1 d(yx x1)] [xk d1 d(yx xk)]
Decimal 27 38 y c1 c2 [x1 d1 d(yx x1)] [xk d1 d(yx xk)]
[Range] y = 3
32Љc1Љc2 126Љ
0Љx 12(Font AЉ - 12 x 24)
0 x 9(Font BЉЉ - 9 x 24)
0Љd 255Љ
k = c2 – c1 + 1
[Default] None
[Description] Defines user-defined characters from character code check c1 to c2.
y specifies the number of bytes in the vertical direction.
x specifies the number of dots in the horizontal direction.
d is the dot data for the user-defined characters.
[Notes]
Character codes from the alphanumeric characters 20H (decimal 32) to 7EH(decimal
126)) can be defined.
37 Preliminary Rev. 02