Cino MP3200 Printer User Manual


 
Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( k Code49<Function 967>
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 39 43 n
Decimal 29 40 107 3 00 57 67 n
[Range] (pL + pH x256) = 3 (pL = 3, pH =0)
cn = 57, fn = 67
1 n 255
[Default] n = 2
[Description] Specifies the width of narrow element.
[Notes]
Settings of this function affect the processing of Functions 981.
The setting unit differs, depending on the printer models.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}.
154 Preliminary Rev. 02