VERSAJET MP3200
GS ( k PDF417<Function 080>
[Format] ASCII GS ( k pL pH cn fn m d1 dk
Hex 1D 28 6B pL pH 30 50 30 d1 dk
Decimal 29 40 107 pL pH 48 80 48 d1 dk
[Range] 4 (pL + pH x 256) 65535 (0 pLҏ255, 0 pH ҏ255)
cn = 48, fn = 80, m = 48, 0 d 255, k = (pL + pH x256) – 3
[Description] Stores the PDF417 symbol data (d1...dk) in the symbol save area.
[Notes]
Data stored in the symbol save area by this function are processed by Function 081 and
082. The data in the symbol save area are reserved after processing Function 081.
k bytes of d1...dk are processed as symbol data.
Specify only the data code word of the symbol with this function. Be sure not to include
the following data in the data d1...dk because they are added automatically by the printer.
 Start pattern and stop pattern.
 Indicator code word of left and right.
 The descriptor of symbol length (the first code word in the data area).
 The error correction code word calculated by modulus 929.
Settings of this function are effective until the following processing is performed:
 Function 080 is executed. ( Function 080 or 180 or 280 or 780 or 880 or 980 is
executed)
 ESC @ is executed.
 The printer is reset or the power is turned off.