Cino MP3200 Printer User Manual


 
Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( k Code49<Function 968>
[Range] (pL + pH x 256) = 3 (pL = 3, pH =0)
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 39 44 n
Decimal 29 40 107 3 00 57 68 n
cn = 57, fn = 68
1 n 255
[Default] n = 16
[Description] Specify the height of one row.
[Notes]
Settings of this function affect the processing of Functions 981.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
The module height influences the recognition rate of the symbol.
For Code49, the minimum recommended symbol height is 8X, where X is the width of
narrow element (reference <Function 967>).
The setting unit is 0.1 mm.
155 Preliminary Rev. 02