Cino MP3200 Printer User Manual


 
Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( k Datamatrix <Function 780>
[Format] ASCII GS ( k pL pH cn fn m d1…dk
Hex 1D 28 6B pL pH 37 50 30 d1…dk
Decimal 29 40 107 pL pH 55 80 48 d1…dk
[Range] 4 ҏ(pL + pH x ҏ256) ҏ65535 (0 ҏpLҏ255, 0 ҏpH ҏ255)
cn = 55
fn = 80
m = 48
0 ҏd ҏ255
k = (pL + pH xҏ256) – 3
[Description] Stores the Datamatrix symbol data (
d1...dk) in the symbol save area.
[Notes]
Data stored in the symbol save area by this function are processed by Function 781. The
data in the symbol save area are reserved after processing Function 781 .
k bytes of d1...dk are processed as symbol data.
Specify only the data code word of the symbol with this function. Be sure not to include
the following data in the data
d1...dk because they are added automatically by the
printer.
 Start pattern and stop pattern
 ndicator code word of left and right
 The descriptor of symbol length (the first code word in the data area)
 The error correction code word calculated by modulus 929
Settings of this function are effective until the following processing is performed:
 Function 080 or 180 or 280 or 780 or 880 or 980 is executed
 ESC @ is executed
 The printer is reset or the power is turned off
144 Preliminary Rev. 02