Cino MP3200 Printer User Manual


 
Command Descriptions
Programming Reference
VERSAJET MP3200
For UPC-A (m = 0, 65) process
Modular check character is processed as follows:
 Automatically added when processing data is 11 byte.
 The 12th byte data is processed as a modular check character when processing data
is 12 byte. In this case, modular check character is not checked.
Left guard bar/center bar/right guard bar are added automatically.
For UPC-E (m = 0, 66) process
The first data (d1) is processed as number system character (NSC) so 0 must be
specified.
 Modular check characters are data to decide bar code pattern, they are not included
printing data.
If n is out of the specified range or if n is an odd number when ITF bar code system (m =
70) is selected, this command is canceled and the following data is processed as normal
data.
Modular check character is processed as follows:
 Automatically added when processing data is 11 byte.
 The 12th byte data is processed as a modular check character when processing data
is 12 byte. In this case, modular check character is not checked.
165 Preliminary Rev. 02