Dell R905 Server User Manual


 
30 About Your System
E201F DRAC Config Remote access controller
(RAC) configuration
failure.
Check screen for specific
error messages. Ensure
that the RAC card and
cables are properly seated.
See "RAC Card" on
page 83. If problem
persists, see your RAC
documentation.
E2020 CPU Config CPU configuration
failure.
Check screen for specific
error messages.
E2021 Memory
Population
Incorrect memory
configuration. Memory
population order
incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 156.
E2022 POST Fail General failure after
video.
Check screen for specific
error messages.
E2110 MBE DIMM ##
& ##
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE).
See "Troubleshooting
System Memory" on
page 156.
E2111 SBE Log
Disable DIMM
##
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and will not resume
logging further SBEs until
the system is rebooted.
"##" represents the
DIMM implicated by the
BIOS.
See "Troubleshooting
System Memory" on
page 156.
Table 1-7. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions