Dell R905 Server User Manual


 
40 About Your System
Shutdown failure Shutdown test failure. See "Troubleshooting
System Memory" on
page 156.
The amount of
system memory has
changed
Memory has been added
or removed or a memory
module may be faulty.
If memory has been added
or removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to
determine if single-bit or
multi-bit errors were
detected and replace the
faulty memory module. See
"Troubleshooting System
Memory" on page 156.
This system
supports only
Opteron
n
series
processors.
Microprocessor(s) is not
supported by the system.
Install a supported
microprocessor or
microprocessor
combination. See
"Installing a Processor" on
page 101.
Time-of-day clock
stopped
Faulty battery or faulty
chip.
See "Troubleshooting the
System Battery" on
page 153.
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program" on
page 43. If the problem
persists, replace the system
battery. See "System
Battery" on page 115.
Timer chip counter
2 failed
Faulty system board. See "Getting Help" on
page 179.
TPM failure A Trusted Platform
Module (TPM) function
has failed.
See "Getting Help" on
page 179.
Table 1-8. System Messages (continued)
Message Causes Corrective Actions