Dell R905 Server User Manual


 
About Your System 35
Error: Incorrect
memory
configuration
CPU
n
The DIMM group for
CPU n is incorrectly
configured and caused
the system to halt.
See "General Memory
Module Installation
Guidelines" on page 92 for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 156.
!*** Error: Remote
Access Controller
initialization
failure *** RAC
virtual USB
devices may not be
available...
Remote Access Controller
initialization failure
Ensure that the Remote
Access Controller is
properly installed. See
"Installing an Optional
RAC Card" on page 83.
Gate A20 failure Faulty keyboard
controller; faulty system
board.
See "Getting Help" on
page 179.
General failure The operating system is
unable to carry out the
command.
This message is usually
followed by specific
information. Note the
information and take the
appropriate action to
resolve the problem.
HyperTransport
error caused a
system reset:
HyperTransport
device
Please check the
system event log
for details.
A fatal system error
occurred and caused the
system to reboot.
Check the SEL for
information that was
logged during the error. See
the applicable
troubleshooting section in
"Troubleshooting Your
System" on page 143 for
any faulty components
specified in the SEL.
Table 1-8. System Messages (continued)
Message Causes Corrective Actions