EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Microsoft Windows 2003 [x64]
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
358 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 540, 620,
630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SP520, SP720, SR1010;
Compusys ProManaged: 5299XN, SC5400PSL,
SR4850HW4, SR6850HW4;
Digital Henge INNO: FS7000, HR−4850,
HR−4850T, HR−6850, HR−6850T;
Digital Henge Revo: LP5299, LS5400;
Gateway 9715;
HCL Infiniti Global Line 2700: OW, SO, ST;
HCL Infiniti Global Line 4700: FC, HW, HW−2;
IBM eServer 326m (Model 7969);
Intel: S7000FC4UR,
SC5299/SC5400/S5000PSLROMB,
SR2520/S5000VSA,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520,
NF520D2;
Lenovo SureServer R630: G5, G7;
Lenovo SureServer: R650, R650 G5, T650;
MPC NetFRAME: 640, 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SL5299, SL5400,
SR4850, SR6850;
Ockam: Duo OSPSL−4200, ES OS−6400;
PowerLeader: PR4850, PR4850Q, PR6850,
PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T, ZSS232;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U, Z2503,
Z4402;
Wortmann TERRA AQUA: 8100, 8200;
Wortmann TERRA SERVER: 6401, 6501
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2,
Edition R2 SP2, Edition SP2
PCI
Express
QLogic
QLE2460−E−SP
4, 6, 7,
18, 19
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25,
32
See
1
359 Dell PowerEdge: 1800, 1950, 1950 III, 2850,
2900 III, 2950 III, 2970, 6800, 6850, 6950, R805,
R900, R905;
HPQ Proliant: DL320 (G5), DL360 (G5), DL380
(G4), DL380 (G5), DL385 (G2), DL580 (G3)
28
,
DL580 (G4), DL585 (G2), ML350 (G5)
28
, ML370
(G5)
28
, ML570 (G3)
28
, ML570 (G4)
28
;
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3350 (4192,4193), x3455 (7940),
x3455 (7984), x3550 (7978), x3650 (7979),
x3655 (7985), x3755 (8877), x3800/x260 (8866),
x3850/x366 (8864), x3850M2 (7141)
27
, x3950M2
(7141)
27
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2,
Edition R2 SP2, Edition SP2
PCI
Express
QLogic
QLE2460−E−SP
4, 6, 7,
18, 19
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
1
360 IBM xSeries: x3850M2 (7233, 7234), x3950M2
(7233, 7234)
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2,
Edition R2 SP2, Edition SP2
PCI
Express
QLogic
QLE2460−E−SP
4, 6, 7,
18, 19
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 32
361 HPQ Proliant: DL320 (G5), DL360 (G5), DL380
(G4), DL380 (G5), DL385 (G2), DL580 (G3)
28
,
DL580 (G4), DL585 (G2), ML350 (G5)
28
, ML370
(G5)
28
, ML570 (G3)
28
, ML570 (G4)
28
;
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3850M2 (7141)
27
, x3950M2
(7141)
27
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2,
Edition R2 SP2, Edition SP2
PCI
Express
QLogic
QLE2560−E−SP
7, 18, 19
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
1
CLARiiON AX150
03/04/2009 115 CLARiiON AX150