EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Microsoft Windows 2003 [x86]
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
293 Dell PowerEdge: 1900, 2900, 2950, 6950 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
Emulex LP982−E
2, 6, 15, 27, 28, 38
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1, 26
See
30
294 Dell PowerEdge 2950 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
Emulex LPe11002−E
2, 5, 6, 15, 28, 35, 45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1, 26
See
30
295 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III,
2950, 2950 III, 2970, 6950
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
Emulex: LP1050Ex−E
2, 5, 6, 15, 27, 28, 35
,
LPe111−E
2, 4, 5, 6, 15, 35, 57
, LPe1150−E
2,
5, 6, 15, 28, 35, 45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1, 26
See
30
296 IBM xSeries x3655 (7985) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
Emulex: LPe12000−E
2, 5, 15, 35, 36
,
LPe12002−E
2, 5, 15, 35, 36
;
IBM: 42D0485 (LPe12000)
5, 6, 15, 35, 36,
63
, 42D0494 (LPe12002)
5, 6, 15, 35, 36, 62
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1, 26, 40
See
31
297 Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
HPQ A7388A (LP1050)
2, 6, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1
298 HPQ Proliant: DL385 (G5), DL580 (G5), DL585
(G2)
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
HPQ AD167A/FC2143 (LP1150)
5, 6, 45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1
299 HPQ Proliant: DL 585 (G5), DL585 (G5) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)
5, 6,
15, 35, 45
, AD167A/FC2143 (LP1150)
5, 6,
15, 35, 45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1
300 HPQ Proliant DL 585 (G5) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)
5, 6,
15, 45
, AD167A/FC2143 (LP1150)
5, 6, 15,
45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1
301 IBM xSeries: x3550 (7978), x3650 (7979), x3655
(7943), x3655 (7985), x3755 (8877)
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP2
7
,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP2
7
,
SP2
PCI
Express,
PCI−X
IBM: 42D0485 (LPe12000)
5, 6, 15, 35, 36,
63
, 42D0494 (LPe12002)
5, 6, 15, 35, 36, 62
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1, 26, 40
See
30, 31
CLARiiON AX150
03/04/2009 163 CLARiiON AX150