EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
8 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2);
IBM xSeries: x336 (8837)
71
,
x3550 (7978), x3650 (7979),
x3800/x260 (8866), x3850/x366
(8864);
NEC Express 5800 140He
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP982−E
2, 11, 23, 34
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
9 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
Fujitsu Siemens Primergy: RX200
S3, RX600 S3, TX600 S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G4)
33
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LPe1150−E
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
10 HPQ Proliant: DL385 (G2), DL585
(G2)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 11, 12
, LP11002−E
1, 2,
11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
11 HPQ Proliant: DL360 (G5), DL585
(G2), ML370 (G5)
33
, ML570
(G4)
33
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ A8002A/FC2142SR (LPe1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
12 HPQ Proliant DL585 (G2) VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 49
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
13 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
14 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G3)
33
, ML570 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ AE311A/FC1142SR (QLE2460)
12, 32, 49
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
15 NEC Express 5800: 120Li,
120Rg−1, 120Ri−2, 140He
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
NEC N8190−120 (LP1050)
2, 11, 35, 61
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
16 Fujitsu Siemens Primergy: RX200
S3, TX300 S3, TX600 S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G4)
33
;
IBM xSeries: x336 (8837)
71
, x346
(8840), x3550 (7978), x3650
(7979), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
QLogic QLA2340−E−SP
38, 39, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
17 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G4)
33
;
IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7985), x3850/x366
(8864)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
QLogic QLA2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
18 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G3)
33
, ML570 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326m (Model 7969),
xSeries x3550 (7978), xSeries
x3650 (7979), xSeries x3655
(7985), xSeries x3755 (8877),
xSeries x3800/x260 (8866),
xSeries x3850/x366 (8864)
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
QLogic QLE2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
19 Fujitsu Siemens Primergy:
RX300, RX300 S2, RX600 S2,
TX300, TX300 S2
VMware ESX Server
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
PCI−X Emulex LP1050−E
2, 11, 12, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150
03/04/2009 860 CLARiiON AX150