EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Red Hat RHEL [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
899 HPQ Proliant DL785 (G5);
IBM xSeries x3950M2 (7141)
23
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
QLogic: QLE2560−E−SP
3,
18, 19, 20
, QLE2562−E−SP
3,
18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1, 21
900 IBM xSeries x3350 (4192,4193) Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
QLogic: QLE2560−E−SP
3,
18, 19, 20
, QLE2562−E−SP
3,
18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
17
See
1, 21
901 IBM xSeries x3455: (7940), (7984);
IBM xSeries x3850M2 (7141)
23
;
Sun Sun Fire: X2200−M2, X4140, X4150, X4240
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
QLogic: QLE2560−E−SP
3,
18, 19, 20
, QLE2562−E−SP
3,
18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1, 21
902 Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
Sun SG−XPCI1FC−EM4−Z:
(LP11000)
3, 12, 14, 25
,
(LP11000)
3, 12, 14, 40
;
Sun SG−XPCIE1FC−EM4:
(LPE11000)
3, 12, 14, 25
,
(LPE11000)
3, 12, 14, 40
;
Sun SG−XPCIE2FC−EM4:
(LPE11002)
3, 12, 25, 26, 37
,
(LPE11002)
3, 12, 26, 37, 40
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
903 Sun Sun Fire: X2200−M2, X4140, X4150, X4240 Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
Sun:
SG−XPCIE1FC−EM8−Z
(LPe12000)
3, 12, 28, 85
,
SG−XPCIE1FC−QF8−Z
(QLE2560)
3, 18, 19, 20
,
SG−XPCIE2FC−EM8−Z
(LPe12002)
3, 12, 28, 85
,
SG−XPCIE2FC−QF8−Z
(QLE2562)
3, 18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1, 21
904 Sun Sun Blade Server Module X6240 Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)
3, 12, 37, 40
,
SG−XPCIE2FC−QB4−Z
(QEM2462)
3, 18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
1
905 Sun Sun Blade Server Module: X6220, X6250, X6450,
X8440
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express
Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)
3, 12, 37, 40
,
SG−XPCIE2FC−QB4−Z
(QEM2462)
3, 18, 19, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
906 HPQ Proliant: DL360 (G5), DL365, DL385 (G2), DL585
(G2), ML350 (G5)
63
, ML370 (G5)
63
, ML570 (G3)
63
,
ML570 (G4)
63
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express,
PCI−X
Emulex LP1050−E
12, 15, 40,
105
;
HPQ A8002A/FC2142SR
(LPe1150)
3, 12, 14, 40
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
907 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL360 (G5), DL365, DL385 (G2), DL585
(G2), ML350 (G5)
63
, ML370 (G5)
63
, ML570 (G3)
63
,
ML570 (G4)
63
;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express,
PCI−X
Emulex LP1050−E
3, 12, 15,
40
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
908 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL360 (G5), DL365, DL385 (G2), ML350
(G5)
63
, ML370 (G5)
63
, ML570 (G4)
63
;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
5.2
5, 7, 8, 9,
22
PCI
Express,
PCI−X
Emulex LP1050Ex−E
3, 12,
15, 40
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
CLARiiON AX150
03/04/2009 705 CLARiiON AX150