EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
263 HPQ Proliant: BL25p, BL35p VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI−X
20
HPQ Emulex−based BL25/30/35/45p Fibre
Channel Mezzanine HBA − 394588−B21
2, 11, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
264 HPQ Proliant BL20p: (G3), (G4);
HPQ Proliant BL25p (G2)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI−X
20
HPQ: Emulex−based BL20p G3 Fibre Channel
Mezzanine HBA − 394757−B21
2, 11, 23
, HP
QLogic−based Fibre Channel Mezzanine HBA
for BL20p G3/BL20p G4 361426−B21
22, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
265 Dell PowerEdge 1955 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI, PCI
Express,
PCI−X
Dell 2342M
38, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
266 HPQ Proliant DL380: (G4), (G5) VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 11, 12
, LP11002−E
1, 2,
11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
267 HPQ Proliant: DL380 (G4), DL580
(G3)
33
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI,
PCI−X
Emulex LP1050Ex−E
2, 11, 12, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
268 HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)
33
, DL580
(G3)
33
, DL585, ML370 (G3)
33
,
ML370 (G4)
33
;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI,
PCI−X
Emulex LP982−E
2, 11, 23, 34
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
269 HPQ Proliant DL380 (G3) VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI,
PCI−X
Emulex: LP11000−E
1, 2, 11, 12
, LP11002−E
1, 2,
11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
270 HPQ Proliant DL380: (G3), (G4);
HPQ Proliant: DL385, DL580
(G2)
33
, DL580 (G3)
33
, DL585,
ML370 (G3)
33
, ML370 (G4)
33
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI,
PCI−X
HPQ AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
271 IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI,
PCI−X
IBM 24P0960 (QLA2340)
38, 43, 63
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
272 HPQ Proliant: DL380 (G3), DL580
(G2)
33
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI HPQ AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
273 HPQ Proliant: DL380 (G4), DL580
(G3)
33
, ML370 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI
Express
HPQ: A8002A/FC2142SR (LPe1150)
1, 2, 11, 12
,
AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
274 Dell PowerEdge 1855 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI−X Dell LPe1105−M
1, 11, 12, 60
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
275 HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI−X HPQ AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
276 Dell PowerEdge 1955 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
Dell LPe1105−M
1, 11, 12, 60
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
277 Dell PowerEdge: 1850, 1950,
2800, 2850, 6800, 6850
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express
QLogic QLE2460−E−SP
12, 32, 43, 59
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
278 Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
5, 6, 7, 8, 9, 10, 40
PCI−X HPQ AB429A/FC1143 (QLA2460)
12, 32, 43
;
QLogic QLA2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
279 HPQ Proliant DL380 (G5) VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
5, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 43
;
QLogic QLA2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
280 HPQ Proliant: DL380 (G4),
DL385, ML370 (G4)
33
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
5, 6, 7, 8, 9, 10, 40
PCI,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
281 HPQ Proliant DL585 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
,
3.0
5, 6, 7, 8, 9, 10, 40
PCI,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 49
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150
03/04/2009 877 CLARiiON AX150