EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Sun Solaris
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
17 Sun Netra: 1290
1
, N240
1
, N440
1
;
Sun Sun Fire: 12K
1
, 15K, 20k, 25k, 2900
1
, 6900
1
, E4900
Sun Solaris 9
04/04
15, 48
PCI QLogic
QLA2460−E−SP
20,
25, 26, 29, 30, 31, 34, 43,
44, 45, 46, 47
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
40
See
41, 42
18 Sun Sun Fire V250
1
Sun Solaris 9
08/03
15, 48
PCI QLogic
QLA2460−E−SP
20,
25, 26, 29, 30, 31, 34, 43,
44, 45, 46, 47
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
40
See
41, 42
19 Sun Sun Fire: V240
1
, V440 Sun Solaris 9
12/03
15, 48
PCI QLogic
QLA2460−E−SP
20,
25, 26, 29, 30, 31, 34, 43,
44, 45, 46, 47
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
40
See
41, 42
20 Sun Sun Fire: V215
1
, V245, V445 Sun Solaris 9 S9
HW: 9/05
15
;
Sun Solaris 9
Solaris 9 HW
09/05
15
PCI
Express,
PCI−X
QLogic
QLA2460−E−SP
20,
25, 26, 29, 30, 31, 34, 43,
44, 46, 52
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
40
21 Sun: Netra 1290
1
, Sun Fire 280R, Sun Fire 2900
1
, Sun Fire
4800
1
, Sun Fire 4810, Sun Fire 6800, Sun Fire 6900
1
, Sun Fire
E4900, Sun Fire V100
1
, Sun Fire V120, Sun Fire V1280
1
, Sun
Fire V210
1
, Sun Fire V250
1
, Sun Fire V480
1
, Sun Fire V490
1
,
Sun Fire V880, Sun Fire V890
Sun Solaris 9
15
PCI QLogic
QLA2340−E−SP
3, 4,
21, 22, 23, 24, 26, 27, 28,
29, 30, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
N
22 Sun Sun Fire: 280R, 2900
1
, 4800
1
, 4810, 6800, 6900
1
, E4900,
V100
1
, V120, V1280
1
, V250
1
, V480
1
, V490
1
, V880, V890
Sun Solaris 9
15
PCI Sun X6767A
(SG−XPCI1FC−QF2)
20,
25, 29, 30, 31, 32, 33, 34,
35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
N
23 Sun Sun Fire: V240
1
, V440 Sun Solaris 9
15,
48
PCI QLogic
QLA2340−E−SP
3, 4,
21, 22, 23, 24, 26, 27, 28,
29, 30, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
N
24 Sun Netra: 120
1
, 1280
1
, 1400
1
, 1405
1
, 20;
Sun Sun Blade: 1000
1
, 1500
1
, 150
1
, 2000
1
, 2500
1
;
Sun Sun Fire: 12K
1
, 15K, 20k, 25k, 280R, 4800
1
, 4810, 6800,
V100
1
, V120, V1280
1
, V210
1
, V240
1
, V440, V480
1
, V490
1
,
V880, V890
Sun Solaris 9
15,
48
PCI QLogic
QLA2460−E−SP
20,
25, 26, 29, 30, 31, 34, 43,
44, 45, 46, 47
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
40
See
41, 42
25 Sun Sun Blade: 1000
1
, 1500
1
, 2000
1
, 2500
1
;
Sun Sun Fire: V210
1
, V240
1
, V440
Sun Solaris 9
15,
48
PCI Sun X6767A
(SG−XPCI1FC−QF2)
20,
25, 29, 30, 31, 32, 33, 34,
35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
N
1. Must add "set sd:sd_io_time=60", "set sd:sd_max_throttle=20", "set ssd:ssd_io_time=60", and "set ssd:ssd_max_throttle=20" in the /etc/system file for Symmetrix or CLARiiON
attach. Do not include quotes on these entries.
2. Driver Version V2.28 (Sun Patch 125166−11)
3. Driver Version 4.17 Must add "set sd:sd_max_throttle=20" in /etc/system for Symmetrix attach.
Must add "forceload: drv/sd" in the /etc/system when these HBA's are installed for Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
4. Driver Version 4.22 Must add "set sd:sd_max_throttle=20" in /etc/system for Symmetrix attach.
Must add "forceload: drv/sd" in the /etc/system when these HBA's are installed for Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
5. Driver Version SAN in Solaris 10 U1 (01/06)
6. Driver Version V2.26 (Sun Patch 125166−10)
7. Driver Version V2.29 (Sun Patch 125166−12)
8. Supports S10 Update 6 (10/08)
9. EMC supports ZFS in Solaris 10 11/06 (update 3) or later. The Snapshot and Clone features of ZFS are supported only through Sun Microsystems.
10. Supports S10 Update 5 (05/08)
11. Supports S10 Update 4 (08/07).
12. EMC requires Sun patches for Solaris 10:
118833−36 SunOS 5.10: Kernel patch.
120011−14 SunOS 5.10: Kernel patch.
127127−11 SunOS 5.10: Kernel patch.
137137−09 SunOS 5.10: Kernel patch.
138888−03 SunOS 5.10: Kernel patch.
119130−33 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver) .
125184−10 SunOS 5.10: Sun Fibre Channel Device Drivers.
120222−30 SunOS 5.10: Emulex−Sun LightPulse fibre channel adapter driver v2.31o (only required for Emulex HBAs running Leadville).
125166−12 SunOS 5.10: Qlogic ISP fibre channel device driver v2.29 (only required for Qlogic HBAs running Leadville).
139579−02 SunOS 5.10: zfs Patch.
13. Supports S10 Update 1 (01/06)
14. For LDOM support, please refer to the 'Virtualization Server Support' table available via EMC PowerLink:
https://elabnavigator.emc.com/emcpubs/elab/esm/pdf/Virtualization_Server_Support.pdf
15. For Sun MPxIO support please review the 'Sun StorEdge Traffic Manager for CLARiiON Release Notes (P/N 300−002−978)' available via EMC PowerLink.
16. Supports S10 Update 2 (06/06)
17. If setting the boot disk from SAN with Solaris 10, its Target/LUN must be defined in the /kernel/drv/sd.conf file.
18. STMS (MPxIO) is supported with the following patch installed: 119715−09
19. Supports S10 Update 3 (11/06)
20. SNIA HBA API Supported.
21. FCode Value 1.14.15 Fcode should be loaded on all HBA's at the time of initial installation. This should only be done before configuring devices, and should not be done after devices
are configured. If HBA does not contain Fcode and Fcode is loaded after devices are configured, the device paths will change and this could result in loss of data.
22. FCode Value 1.14.13 Fcode should be loaded on all HBA's at the time of initial installation. This should only be done before configuring devices, and should not be done after devices
are configured. If HBA does not contain Fcode and Fcode is loaded after devices are configured, the device paths will change and this could result in loss of data.
23. FCode Value 2.00.09 Fcode should be loaded on all HBA's at the time of initial installation. This should only be done before configuring devices, and should not be done after devices
are configured. If HBA does not contain Fcode and Fcode is loaded after devices are configured, the device paths will change and this could result in loss of data.
24. FCode Value 2.00.06
25. STMS is Sun's Multipathing Software and not an EMC Software product. Please refer to the required release note "SUN StorEdge Traffic Manager for CLARiiON Release Notes", P/N
300−002−978, which can be found on EMC's Powerlink website in Support −> Document Library −> Host Connectivity for the complete Installation information.
26. For servers running Solaris 8 or 9 with the Sun SAN driver, the following applies:
Must add "set fcp:ssfcp_enable_auto_configuration=1" (do not include quote marks) in /etc/system to fix the following problems:
1. VxVM − rootdg can not be imported during boot
2. SVM − Volume Manager can not be started after system boot
3. PowerPath 4.x − error message "All paths to (array type) (array name) vol(volume number) are dead"
27. Driver Version SAN 4.4.12 Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath. (do not include the quotes on either entry).
Driver version SAN 4.3 or older is not supported for MPxIO on EMC storage arrays.
28. Driver Version 4.15.03 Must add "set sd:sd_max_throttle=20" in /etc/system for Symmetrix attach.
Must add "forceload: drv/sd" in the /etc/system when these HBA's are installed for Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
29. Driver Version SAN 4.4.15
30. Driver Version SAN 4.4.13
31. Driver Version SAN 4.4.14
32. FCode Value 1.14.11
33. FCode Value 1.14.15
34. Driver Version SAN 4.4.12
35. Sun StorEdge Traffic Manager Software (Sun's Native Multipathing Software) is supported on CLARiiON with SAN 4.4.7a and above.
CLARiiON AX150
03/04/2009 857 CLARiiON AX150