Red Hat RHEL [32−Bit]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
1004 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant DL585 (G2);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe12000−E
3, 17,
45, 103
;
QLogic: QLE2560−E−SP
1,
3, 30, 31
, QLE2562−E−SP
1,
3, 30, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1005 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe12002−E
3, 17,
45, 103
;
QLogic QLE2560−E−SP
1, 3,
31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
27
1006 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)
47
, ML370 (G5)
47
, ML570
(G3)
47
, ML570 (G4)
47
;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877)
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe12002−E
3, 45,
103
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
27
1007 Fujitsu Siemens Primergy: BX620 S4, RX200 S4, RX600
S4, TX300 S4
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe1250−E
3, 17, 45,
103
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
28
1008 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)
47
, ML370 (G5)
47
, ML570
(G3)
47
, ML570 (G4)
47
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe1250−E
3, 45,
103
;
QLogic QLE2560−E−SP
1, 3,
30, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
27
1009 HPQ Proliant DL 585 (G5) Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex: LP1050−E
16, 17,
18, 49, 53
, LP1050−E
17, 49,
53, 103
, LP1050−E
3, 16, 17,
18, 49
, LP1050−E
3, 17, 49,
103
, LP11000−E
3, 12, 16, 17,
18
, LP11000−E
3, 12, 17, 103
,
LP1150−E
3, 12, 16, 17, 18
,
LP1150−E
3, 12, 17, 103
,
LPe11000−E
3, 12, 16, 17, 18
,
LPe11000−E
3, 12, 17, 103
,
LPe11002−E
3, 12, 17
,
LPe11002−E
3, 12, 17, 103
;
HPQ AB429A/FC1143:
(QLA2460)
1, 3, 30, 31
,
(QLA2460)
1, 3, 31
;
HPQ AE311A/FC1142SR:
(QLE2460)
1, 3, 30, 31
,
(QLE2460)
1, 3, 31
;
HPQ AE312A/FC1242SR:
(QLE2462)
1, 3, 30, 31
,
(QLE2462)
1, 3, 31
;
HPQ AE369A/FC1243:
(QLA2462)
1, 3, 30, 31
,
(QLA2462)
1, 3, 31
;
HPQ
FCA2214/281541−B21:
(QLA2340)
20, 30, 31
,
(QLA2340)
20, 31
;
HPQ
FCA2214DC/321835−B21:
(QLA2342)
20, 30, 31
,
(QLA2342)
20, 31
;
QLogic: QLA2340−E−SP
3,
30, 31, 73
, QLA2340−E−SP
3,
31, 73
, QLA2342−E−SP
3, 30,
31, 73
, QLA2342−E−SP
3, 31,
73
, QLA2460−E−SP
3, 30, 31,
71
, QLA2460−E−SP
3, 31, 71
,
QLA2462−E−SP
3, 30, 31, 71
,
QLA2462−E−SP
3, 31, 71
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
27
1010 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)
47
, ML370 (G5)
47
, ML570 (G3)
47
, ML570 (G4)
47
Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex: LP1050−E
16, 17,
18, 49, 53
, LP1050−E
3, 16, 17,
18, 49
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
32
See
27
1011 Fujitsu Siemens Primergy BX620 S4 Red Hat
RHEL
[32−Bit]
5.2
4, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex: LP1050−E
16, 17,
18, 54
, LP1050−E
17, 54, 103
,
LP1050−E
3, 16, 17, 18, 54
,
LP1050−E
3, 17, 54, 103
;
Fujitsu Siemens:
BX600−FC22Q
3, 24, 30, 31,
84
, BX600−FC22Q
3, 24, 31,
84
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
32
See
27
CLARiiON AX150
03/04/2009 534 CLARiiON AX150