EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
SuSE SLES [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
87 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM: eServer 326m (Model 7969), xSeries x3550 (7978),
xSeries x3650 (7979), xSeries x3800/x260 (8866), xSeries
x3850/x366 (8864);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2360−E−SP
15, 27, 28
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
88 IBM xSeries x3655 (7985) SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2360−E−SP
15, 27, 28
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
89 Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX200
S4, RX600 S3, RX600 S4, TX300 S3, TX300 S4, TX600
S3
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP
1, 13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
22
90 HPQ Proliant DL360 (G5) SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP
1, 13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
58
See
22
91 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
Fujitsu Siemens Primergy: RX200 S4, RX600 S4, TX300
S4;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
IBM: eServer 326m (Model 7969), xSeries x3800/x260
(8866), xSeries x3850/x366 (8864);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP
13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
92 Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX600
S3, TX300 S3, TX600 S3;
HPQ Proliant: DL360 (G5), DL365, DL585 (G2);
IBM xSeries: x3655 (7985), x3755 (8877)
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP
13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
93 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
Hewlett Packard Proliant ML350: (G4), (G4p);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic:
QLA2460−E−SP
1, 13, 27
,
QLA2462−E−SP
1, 13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
94 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)
40
, ML370 (G5)
40
, ML570
(G4)
40
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
QLogic:
QLA2460−E−SP
1, 13, 27
,
QLA2462−E−SP
1, 13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
95 Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2 SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Sun:
SG−XPCI1FC−EM4−Z
(LP11000)
1, 10, 11, 37, 38,
47
,
SG−XPCI2FC−EM4−Z
(LP11002)
1, 10, 11, 37, 38,
47
, SG−XPCIE1FC−EM4
(LPE11000)
10, 11, 37, 38,
47
, SG−XPCIE2FC−EM4
(LPE11002)
10, 37, 38, 47,
50, 51
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
CLARiiON AX150
03/04/2009 791 CLARiiON AX150