VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
228 Dell PowerEdge: 1850, 2850,
2900, 2950, 6950
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI
Express,
PCI−X
QLogic: QLA2310F−E−SP
29, 39, 81
,
QLE2360−E−SP
12, 29, 50
, QLE2362−E−SP
12, 29,
50
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
229 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850, 6950
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI
Express,
PCI−X
QLogic: QLA2340−E−SP
29, 39, 52
,
QLA2342−E−SP
29, 39, 52
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
230 Dell PowerEdge: 2900, 2950,
6950
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI
Express,
PCI−X
QLogic: QLE2460−E−SP
12, 29, 32, 59
,
QLE2462−E−SP
12, 29, 59
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
231 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI
Express,
PCI−X
QLogic: QLE2460−E−SP
12, 29, 32
,
QLE2462−E−SP
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
232 HPQ Proliant: DL380 (G5), DL580
(G5)
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP10000−E
2, 23, 26
, LP10000DC−E
2,
23, 26
, LP1050−E
2, 23, 26
, LP1050DC−E
2, 23, 26
,
LP1050Ex−E
2, 12, 23, 26
, LP8000−EMC
26, 37, 42
,
LP9002−E (LP9002L−E)
2, 26, 37
, LP9802−E
2, 26,
35, 36
, LP9802DC−E
2, 23, 26, 34
, LP982−E
2, 23,
26, 34
, LPe11002−E
1, 2, 12, 26
, LPe1150−E
1, 2, 12,
26
;
HPQ: A8002A/FC2142SR (LPe1150)
1, 2, 12, 26
,
A8003A/FC2242SR (LPe11002)
1, 2, 12, 26
,
AD167A/FC2143 (LP1150)
1, 2, 12, 26
,
AD168A/FC2243 (LP11002)
1, 2, 12, 26
,
AE311A/FC1142SR (QLE2460)
12, 29, 32
,
AE312A/FC1242SR (QLE2462)
12, 29, 32
,
FCA2214/281541−B21 (QLA2340)
29, 38
,
FCA2214DC/321835−B21 (QLA2342)
29, 38
;
QLogic: QLA2200F−EMC
29, 41
,
QLA2310F−E−SP
29, 38, 39
, QLA2340−E−SP
29,
38, 39
, QLA2342−E−SP
29, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
233 HPQ Proliant DL580 (G5) VMware ESX Server
3i
6, 7, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 12, 26, 31
, LP11002−E
1,
2, 12, 26, 31
, LP1150−E
1, 2, 12, 26, 31
;
HPQ: AB429A/FC1143 (QLA2460)
12, 29, 31, 32
,
AE369A/FC1243 (QLA2462)
12, 29, 31, 32
;
QLogic: QLA2460−E−SP
12, 29, 31, 32
,
QLA2462−E−SP
12, 29, 31, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
234 HPQ Proliant DL380 (G5) VMware ESX Server
3i
6, 7, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 12, 26
, LP11002−E
1, 2,
12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
235 HPQ Proliant: DL380 (G5), DL580
(G5)
VMware ESX Server
3i
6, 7, 9, 10, 28
PCI, PCI
Express,
PCI−X
QLogic: QLE2460−E−SP
12, 29, 32
,
QLE2462−E−SP
12, 29, 32
, QLE2560−E−SP
12, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
236 Fujitsu Siemens Primergy BX630:
(2−way), (4−way)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI Emulex LP1050−E
2, 11, 12, 23
;
Fujitsu Siemens BX600−FC22Q
12, 49, 52, 72
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
237 Fujitsu Siemens Primergy BX630:
(2−way), (4−way);
HPQ Proliant DL380 (G3)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI Emulex LP1050−E
2, 11, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
238 HPQ Proliant DL380 (G3) VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI Emulex LP982−E
2, 11, 23, 34
;
QLogic QLA2340−E−SP
38, 39, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
239 Fujitsu Siemens Primergy
BX660
73
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI Fujitsu Siemens BX600−FC22Q
12, 43, 52, 72
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
240 Dell PowerEdge: 1950, 6850;
Fujitsu Siemens Primergy RX300
S3;
IBM xSeries x3455 (7984)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express
Emulex LP1050Ex−E
2, 11, 12, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
241 Dell PowerEdge 1950 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express
QLogic QLA2340−E−SP
39, 43, 52
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
242 Dell PowerEdge 6850 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express
QLogic QLE2360−E−SP
12, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
243 Dell PowerEdge 1950;
IBM xSeries x3455 (7984)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express
QLogic QLE2360−E−SP
12, 43, 50
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
244 Dell PowerEdge 6850 VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Dell 2362M
43, 66, 67
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
245 HPQ Proliant: ML370 (G5)
33
,
ML570 (G4)
33
;
IBM xSeries x3755 (8877)
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP1050−E
2, 11, 12, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
246 HPQ Proliant: DL360 (G5), DL385
(G2), ML370 (G5)
33
, ML570
(G4)
33
VMware ESX Server:
3.0.1
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.2
3, 4, 5, 6, 7, 8, 9, 10
,
3.0.3
3, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150
03/04/2009 875 CLARiiON AX150