EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
150 Fujitsu Siemens Primergy: RX200
S4, RX600 S3, RX600 S4, TX300
S4, TX600 S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)
33
,
ML570 (G3)
33
, ML570 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326m (Model 7969),
xSeries x3550 (7978), xSeries
x3650 (7979), xSeries x3655
(7943), xSeries x3655 (7985),
xSeries x3755 (7163), xSeries
x3755 (8877), xSeries
x3800/x260 (8866), xSeries
x3850/x366 (8864)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express,
PCI−X
QLogic: QLE2460−E−SP
12, 29, 32
,
QLE2462−E−SP
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
151 Dell PowerEdge 1855 VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Dell: 2342M
29, 38
, LPe1105−M
1, 12, 26, 60
,
QME2462
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
152 IBM xSeries x346 (8840)
89
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP10000−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
153 Fujitsu Siemens Primergy RX600
S2
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP1050−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
154 Fujitsu Siemens Primergy: RX600
S2, TX600 S2;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP1050Ex−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
155 Dell PowerEdge: 1750, 2600,
2650, 6650;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)
33
, ML570 (G3)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x346
(8840)
89
, xSeries x365, xSeries
x3800/x260 (8865)
65
, xSeries
x3850/x366 (8863)
65
, xSeries
x3950/x3950E/x460 (8872,
8874)
65
, xSeries
x3950/x3950E/x460 (8878, 8879);
NEC Express 5800: 120Rh−2,
140Rd−4
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP8000−EMC
26, 37, 42
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
156 Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP9002−E (LP9002L−E)
2, 12, 26, 37
;
Sun: SG−XPCI1FC−EM2 (LP10000)
2, 26
,
SG−XPCI1FC−EM4−Z (LP11000)
2, 12, 26, 45
,
SG−XPCI1FC−QL2 (QLA2340)
12, 29
,
SG−XPCI2FC−EM2 (LP10000DC)
2, 26
,
SG−XPCI2FC−EM4 (LP11002)
2, 26, 45
,
SG−XPCI2FC−EM4−Z (LP11002)
2, 12, 26, 45
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
157 IBM xSeries x346 (8840)
89
;
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex LP9802−E
2, 12, 26, 35, 36
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
158 Dell PowerEdge: 1750, 2600,
2650, 6650;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)
33
, ML570 (G3)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)
65
,
xSeries x3850/x366 (8863)
65
,
xSeries x3950/x3950E/x460
(8872, 8874)
65
, xSeries
x3950/x3950E/x460 (8878, 8879);
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex: LP10000−E
2, 23, 26
, LP10000DC−E
2,
23, 26
, LP1050−E
2, 23, 26
, LP1050DC−E
2, 23, 26
,
LP9002−E (LP9002L−E)
2, 26, 37
, LP9802−E
2, 26,
35, 36
, LP9802DC−E
2, 23, 26, 34
, LP982−E
2, 23,
26, 34
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
159 IBM xSeries x3950/x3950E/x460
(8878, 8879)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Emulex: LP11000−E
1, 2, 12, 26
, LP11002−E
1, 2,
12, 26
;
IBM: 42D0405 (LP11000)
1, 2, 12, 26
, 42D0407
(LP11002)
1, 2, 12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
160 Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X HPQ: AB429A/FC1143 (QLA2460)
12, 29, 32
,
AE369A/FC1243 (QLA2462)
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150
03/04/2009 870 CLARiiON AX150