Microsoft Windows 2008 [x64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
12 HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
HPQ: A8002A/FC2142SR
(LPe1150)
1, 2, 3, 18, 21, 23
,
A8003A/FC2242SR
(LPe11002)
1, 2, 3, 18, 21, 23
,
AE311A/FC1142SR
(QLE2460)
3, 10, 12, 13, 18
,
AE312A/FC1242SR
(QLE2462)
3, 10, 12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
24
13 HPQ Proliant: DL380 (G4), DL580 (G4), DL785
(G5)
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
HPQ: AJ762A (LPe12000)
2,
3, 18, 21, 23, 25
, AJ763A
(LPe12002)
2, 3, 18, 21, 23, 25
,
AJ764A (QLE2562)
3, 10, 12,
18
, AK344A (QLE2560)
3, 10,
12, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
6, 11
14 Dell PowerEdge: R805, R900, R905 Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
QLogic QLE220−E−SP
3, 10,
12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
11
15 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970 Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
QLogic QLE2460−E−SP
3,
10, 12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
11
16 Dell PowerEdge: R805, R900, R905;
HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
QLogic QLE2460−E−SP
3,
10, 12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
11
17 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970,
R805, R900, R905
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
QLogic QLE2462−E−SP
3,
10, 12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 9
See
11
18 HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express
QLogic QLE2462−E−SP
3,
10, 12, 13, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
11
19 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2)
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LP10000−E
2, 4, 5,
18, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 9, 59
See
6
20 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2), DL585 (G5), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LP1050−E
2, 4, 5, 18,
39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
21 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LP1050DC−E
2, 4, 5,
18, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
22 HPQ Proliant DL585 (G5) Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LP1150−E
1, 2, 3, 18,
21, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
23 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970 Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LPe1150−E
1, 2, 3, 4,
5, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
24 HPQ Proliant: DL385 (G2), DL585 (G2), DL585
(G5)
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex LPe1150−E
1, 2, 3, 4,
5, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
6
25 HPQ Proliant DL360 (G5) Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex: LP10000−E
2, 3, 4,
5, 18, 39
, LP10000DC−E
2, 3,
4, 5, 18, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24, 59
See
6
26 HPQ Proliant: DL585 (G2), ML570 (G4)
31
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex: LP10000−E
2, 3, 4,
5, 18, 39
, LP10000DC−E
2, 3,
4, 5, 18, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
27 HPQ Proliant DL360 (G5) Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 3,
18, 21, 23
, LP11002−E
1, 2, 3,
18, 21, 23
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8
See
6
28 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2)
Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex: LPe11000−E
1, 2, 3,
4, 5, 18
, LPe11002−E
1, 2, 3,
4, 5, 14, 18
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
6
29 HPQ Proliant DL385 (G2) Microsoft
Windows
2008 [x64]
DataCenter
7
PCI
Express,
PCI−X
Emulex: LPe12000−E
2, 3, 4,
5, 25
, LPe12002−E
2, 3, 4, 5,
25
;
HPQ: AJ762A (LPe12000)
2,
3, 18, 21, 23, 25
, AJ763A
(LPe12002)
2, 3, 18, 21, 23, 25
,
AJ764A (QLE2562)
3, 10, 12,
18
, AK344A (QLE2560)
3, 10,
12, 18
;
QLogic: QLE2560−E−SP
3,
10, 12
, QLE2562−E−SP
3, 10,
12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
8, 24
See
6, 11
CLARiiON AX150
03/04/2009 209 CLARiiON AX150