EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Red Hat RHEL [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
1067 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984), x3850M2 (7141)
23
, x3850M2 (7233, 7234),
x3950M2 (7141)
23
, x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic QLE2460−E−SP
4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1068 Sun Sun Fire X4250 Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic QLE2460−E−SP
4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
76, 77,
78
1069 Dell PowerEdge: 1950, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950, R805, R900, R905;
IBM xSeries: x3850M2 (7233, 7234), x3950M2 (7233,
7234)
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic QLE2462−E−SP
3,
4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
1
1070 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193), x3950M2 (7141)
23
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic QLE2462−E−SP
3,
4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1071 Fujitsu Siemens Primergy RX300 S4;
IBM xSeries x3455: (7940), (7984);
IBM xSeries x3850M2 (7141)
23
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic QLE2462−E−SP
3,
4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1
1072 Sun Sun Fire: X4140, X4240, X4440 Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLA2460−E−SP
3,
4, 20
, QLA2462−E−SP
3, 4,
20
;
Sun SG−XPCI2FC−EM4−Z
(LP11002)
3, 12, 14, 127
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1073 IBM xSeries x3350 (4192,4193) Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2360−E−SP
2,
3, 4
, QLE2362−E−SP
2, 3, 4
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1074 IBM xSeries x3455: (7940), (7984) Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2360−E−SP
2,
3, 4
, QLE2362−E−SP
2, 3, 4
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1
1075 Dell PowerEdge: R805, R900, R905;
IBM xSeries: x3850M2 (7233, 7234), x3950M2 (7233,
7234)
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2560−E−SP
3,
4, 20
, QLE2562−E−SP
3, 4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
1, 21
1076 HPQ Proliant DL785 (G5);
IBM xSeries x3950M2 (7141)
23
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2560−E−SP
3,
4, 20
, QLE2562−E−SP
3, 4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1, 21
1077 IBM xSeries x3350 (4192,4193) Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2560−E−SP
3,
4, 20
, QLE2562−E−SP
3, 4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
17
See
1, 21
1078 IBM xSeries x3455: (7940), (7984);
IBM xSeries x3850M2 (7141)
23
;
Sun Sun Fire: X2200−M2, X4140, X4150, X4240
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
QLogic: QLE2560−E−SP
3,
4, 20
, QLE2562−E−SP
3, 4,
20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1, 21
1079 Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
Sun: SG−XPCI1FC−EM4−Z
(LP11000)
3, 12, 14, 41
,
SG−XPCIE1FC−EM4
(LPE11000)
3, 12, 14, 126
,
SG−XPCIE2FC−EM4
(LPE11002)
3, 12, 26, 37, 41
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1080 Sun Sun Fire: X2200−M2, X4140, X4150, X4240 Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
Sun:
SG−XPCIE1FC−EM8−Z
(LPe12000)
3, 12, 41, 85
,
SG−XPCIE1FC−QF8−Z
(QLE2560)
3, 4, 20
,
SG−XPCIE2FC−EM8−Z
(LPe12002)
3, 12, 41, 85
,
SG−XPCIE2FC−QF8−Z
(QLE2562)
3, 4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 17
See
1, 21
1081 Sun Sun Blade Server Module X6240 Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)
3, 12, 37, 41
,
SG−XPCIE2FC−QB4−Z
(QEM2462)
3, 4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
1
1082 Sun Sun Blade Server Module: X6220, X6250, X6450,
X8440
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express
Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)
3, 12, 37, 41
,
SG−XPCIE2FC−QB4−Z
(QEM2462)
3, 4, 20
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1083 HPQ Proliant: DL360 (G5), DL365, DL385 (G2), DL385
(G5), DL585 (G2), DL585 (G5), ML350 (G5)
63
, ML370
(G5)
63
, ML570 (G3)
63
, ML570 (G4)
63
Red Hat
RHEL
[x86_64]
5.3
5, 6, 7, 8,
9
PCI
Express,
PCI−X
Emulex LP1050−E
12, 15, 41,
105
;
HPQ A8002A/FC2142SR
(LPe1150)
3, 12, 14, 41
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
CLARiiON AX150
03/04/2009 719 CLARiiON AX150