SuSE SLES [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
185 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984), x3850M2 (7233, 7234), x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2460−E−SP
13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
186 Fujitsu Siemens Primergy RX300 S3;
IBM xSeries: x3850M2 (7141)
67
, x3950M2 (7141)
67
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2460−E−SP
13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
187 HPQ Proliant DL785 (G5) SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2460−E−SP
13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
44
188 Sun Sun Fire X4250 SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2460−E−SP
13, 29
;
Sun:
SG−XPCIE1FC−QF4
(QLE2460)
29, 65
,
SG−XPCIE2FC−QF4
(QLE2462)
29, 65
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
189 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2462−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
190 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5)
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic
QLE2462−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
22
191 Dell PowerEdge: 1950, 1950 III, 2900 III, 2950 III, 2970,
6800, 6850, R805, R900, R905;
IBM xSeries x3455 (7940)
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic:
QLE2560−E−SP
1, 13, 29
,
QLE2562−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
192 IBM xSeries x3850M2 (7141)
67
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic:
QLE2560−E−SP
1, 13, 29
,
QLE2562−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 58
See
22
193 IBM xSeries x3950M2 (7141)
67
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic:
QLE2560−E−SP
1, 13, 29
,
QLE2562−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
See
22
194 IBM xSeries: x3350 (4192,4193), x3850M2 (7233, 7234),
x3950M2 (7233, 7234)
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
QLogic:
QLE2560−E−SP
1, 13, 29
,
QLE2562−E−SP
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
58
See
22
195 Sun Sun Fire: X4140, X4240, X4440 SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
Sun:
SG−XPCI1FC−EM4−Z
(LP11000)
1, 10, 11, 34
,
SG−XPCI1FC−QF4
(QLA2460)
29, 65
,
SG−XPCI2FC−EM4−Z
(LP11002)
1, 10, 11, 34
,
SG−XPCI2FC−QF4
(QLA2462)
29, 65
,
SG−XPCIE1FC−EM4
(LPE11000)
10, 11, 34
,
SG−XPCIE2FC−EM4
(LPE11002)
10, 34, 50, 51
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
196 Sun Sun Fire: X2200−M2, X4150, X4250, X4450 SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
Sun:
SG−XPCI1FC−EM4−Z
(LP11000)
1, 10, 11, 34
,
SG−XPCIE1FC−EM4
(LPE11000)
10, 11, 34
,
SG−XPCIE2FC−EM4
(LPE11002)
10, 34, 50, 51
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
197 Sun Sun Fire: X2200−M2, X4140, X4150, X4240 SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
Sun:
SG−XPCIE1FC−EM8−Z
(LPe12000)
1, 10, 41, 81
,
SG−XPCIE1FC−QF8−Z
(QLE2560)
1, 13, 29
,
SG−XPCIE2FC−EM8−Z
(LPe12002)
1, 10, 34, 41
,
SG−XPCIE2FC−QF8−Z
(QLE2562)
1, 13, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
58
See
22, 44
198 Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
SuSE
SLES
[x86_64]
10 SP2
5, 6,
7, 20, 24, 30,
31
PCI
Express
Sun:
SG−XPCIE1FC−QF4
(QLE2460)
29, 65
,
SG−XPCIE2FC−QF4
(QLE2462)
29, 65
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 798 CLARiiON AX150