Red Hat RHEL [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
1213 Fujitsu Siemens Primergy BX630: (2−way), (4−way) Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI Emulex: LP1050−E
12, 25,
27, 111
, LP1050−E
3, 12, 25,
27, 111
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1214 Fujitsu Siemens Primergy BX620 S3 Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI Fujitsu Siemens
BX600−FC42e
3, 16, 25, 37,
60
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
17
See
1, 21
1215 Dell PowerEdge: 1950, R805, R900, R905 Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
Emulex LPe11002−E
3, 12,
14, 25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 61
See
1
1216 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800,
6850
Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
Emulex: LP1050Ex−E
3, 12,
15, 25, 27
, LPe111−E
3, 12, 25,
26, 27, 37
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1217 Sun Sun Fire X4250 Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
Emulex: LPe11000−E
3, 12,
14, 25, 27
, LPe11002−E
3, 12,
14, 25, 27
;
Sun: SG−XPCI1FC−EM4−Z
(LP11000)
3, 12, 14, 25
,
SG−XPCIE1FC−EM4
(LPE11000)
3, 12, 14, 25
,
SG−XPCIE2FC−EM4
(LPE11002)
3, 12, 25, 26, 37
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10, 76,
77, 78
See
1
1218 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
Emulex: LPe111−E
3, 12, 14,
25, 27
, LPe1150−E
3, 12, 14,
25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
17
1219 HPQ Proliant DL785 (G5) Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
HPQ A8002A/FC2142SR
(LPe1150)
3, 12, 14, 25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1220 IBM xSeries x3455: (7940), (7984) Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express
IBM: 42C2069
(LPe11000)
3, 12, 14, 25, 27
,
42C2071 (LPe11002)
3, 12,
14, 25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1221 HPQ Proliant: DL360 (G5), DL365, DL385 (G2), DL385
(G5), DL585 (G2), DL585 (G5), ML350 (G5)
63
, ML370
(G5)
63
, ML570 (G3)
63
, ML570 (G4)
63
Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express,
PCI−X
Emulex LP1050−E
12, 15, 25,
27, 105
;
HPQ A8002A/FC2142SR
(LPe1150)
3, 12, 14, 25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
1222 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL360 (G5), DL365, DL385 (G2), DL385
(G5), DL585 (G2), DL585 (G5), ML350 (G5)
63
, ML370
(G5)
63
, ML570 (G3)
63
, ML570 (G4)
63
;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]:
5.1
5, 7, 9,
45
, 5.2
5, 7,
8, 9, 22
PCI
Express,
PCI−X
Emulex LP1050−E
3, 12, 15,
25, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
10
See
1
CLARiiON AX150