SuSE SLES [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
51 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
Fujitsu Siemens Primergy: RX600 S3, TX600 S3;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP1050Ex−E
1,
10, 37, 38, 55, 68
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
52 IBM xSeries: x3655 (7985), x3755 (8877), x3800/x260
(8866)
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP1050Ex−E
1,
10, 37, 38, 55, 68
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
53 IBM xSeries x3655 (7943) SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP1050Ex−E
1,
10, 37, 38, 55, 68
;
IBM: 39M5894
(QLA2460)
1, 13, 27
,
39M5895 (QLA2462)
1, 13,
27
, 42C2069
(LPe11000)
1, 10, 11, 37,
38, 68
, 42C2071
(LPe11002)
1, 10, 11, 37,
38, 68
;
QLogic:
QLA2460−E−SP
13, 27
,
QLE220−E−SP
1, 16, 27
,
QLE2360−E−SP
15, 27, 28
,
QLE2460−E−SP
13, 27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
44
54 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
Hewlett Packard Proliant ML350: (G4), (G4p)
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP11000−E
1, 10,
11, 37, 38, 68
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
55 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)
40
, ML370 (G5)
40
, ML570
(G4)
40
;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP11000−E
1, 10,
11, 37, 38, 68
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
56 HPQ Proliant: DL360 (G5), DL365;
IBM xSeries x3755 (8877)
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP1150−E
1, 10,
11, 37, 38, 68
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14
57 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LP982−E
1, 38, 54,
55, 68, 116
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
58 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)
40
, ML370 (G5)
40
, ML570
(G4)
40
;
IBM xSeries: x3550 (7978), x3650 (7979), x3850/x366
(8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP1
5, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Emulex LPe11000−E
1,
10, 11, 37, 38
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
14, 48,
49
CLARiiON AX150
03/04/2009 787 CLARiiON AX150