Oracle Enterprise Linux [x86_64]
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
237 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM: eServer 326m (Model 7969), xSeries x3655 (7985),
xSeries x3800/x260 (8866), xSeries x3850/x366 (8864);
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
Emulex LP1050Ex−E
10, 17, 26, 37
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
238 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6800, 6850, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
Emulex LP982−E
10, 26, 37, 44
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
239 Hewlett Packard Proliant ML350: (G4), (G4p) Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
Emulex: LP1050−E
17, 26, 37
,
LP982−E
26, 37, 44
;
HPQ: AB429A/FC1143 (QLA2460)
10,
20, 21
, AE369A/FC1243 (QLA2462)
10,
20, 21
;
QLogic QLE220−E−SP
10, 21, 39, 60
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
240 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
Emulex: LPe111−E
9, 10, 17, 26
,
LPe1150−E
9, 10, 17, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
241 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950
Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
Emulex: LPe111−E
10, 17, 26, 41, 42
,
LPe1150−E
7, 9, 10, 26
;
QLogic QLE2460−E−SP
10, 20, 21, 28
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
242 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
IBM 24P0960 (QLA2340)
10, 20, 30, 45
;
QLogic QLE2360−E−SP
10, 20, 22
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
243 IBM xSeries: x3655 (7985), x3755 (8877) Oracle
Enterprise
Linux
[x86_64] 4:
U4
13, 19
,
U5
13, 89
PCI
Express,
PCI−X
IBM: 39M5894 (QLA2460)
10, 20, 21
,
39M5895 (QLA2462)
10, 20, 21
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 378 CLARiiON AX150