VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
173 Dell PowerEdge: 1750, 2600,
2650, 6650
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X QLogic: QLA2310F−E−SP
29, 39, 81
,
QLA2340−E−SP
29, 39, 52
, QLA2342−E−SP
29, 39,
52
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
174 Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM xSeries x3950/x3950E/x460
(8878, 8879)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X QLogic: QLA2460−E−SP
12, 29, 32
,
QLA2462−E−SP
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
175 IBM xSeries x3800/x260 (8865)
65
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X QLogic: QLE2360−E−SP
12, 29, 81
,
QLE2362−E−SP
12, 29, 81
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
176 Sun Sun Fire: X4100, X4200 VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Sun: SG−XPCI1FC−QF4 (QLA2460)
29
,
SG−XPCI2FC−QF4 (QLA2462)
29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
177 Unisys ES7000/one [Xeon] VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X Unisys: FCH7440131−PCX (LP1150)
1, 26, 31, 77
,
FCH7440231−PCX (LP11002)
1, 26, 31, 77
,
FCH752313−PCX (LP1050)
2, 23, 26, 31
,
FCH752323−PCX
31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
48
178 HPQ Proliant BL20p (G2) VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X
20
HPQ Dual−port Fibre Channel Adapter for HP
Proliant BL20p G2 300874−B21
22, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
179 HPQ Proliant BL25p VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X
20
HPQ Dual−port Fibre Channel Adapter for HP
Proliant BL25p/BL45p 381881−B21
22, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
180 HPQ Proliant: BL25p, BL35p VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X
20
HPQ Emulex−based BL25/30/35/45p Fibre
Channel Mezzanine HBA − 394588−B21
2, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
181 HPQ Proliant BL20p: (G3), (G4);
HPQ Proliant BL25p (G2)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI−X
20
HPQ: Emulex−based BL20p G3 Fibre Channel
Mezzanine HBA − 394757−B21
2, 23, 26
, HP
QLogic−based Fibre Channel Mezzanine HBA
for BL20p G3/BL20p G4 361426−B21
22, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
182 Fujitsu Siemens Primergy TX200:
S3, S4
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex LPe11000−E
1, 2, 12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
183 HPQ Proliant: DL380 (G5), DL580
(G4), DL580 (G5)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP10000−E
2, 23, 26
, LP10000DC−E
2,
23, 26
, LP1050−E
2, 23, 26
, LP1050DC−E
2, 23, 26
,
LP1050Ex−E
2, 12, 23, 26
, LP8000−EMC
26, 37, 42
,
LP9002−E (LP9002L−E)
2, 26, 37
, LP9802−E
2, 26,
35, 36
, LP9802DC−E
2, 23, 26, 34
, LP982−E
2, 23,
26, 34
;
HPQ: A8002A/FC2142SR (LPe1150)
1, 2, 12, 26
,
A8003A/FC2242SR (LPe11002)
1, 2, 12, 26
,
AD167A/FC2143 (LP1150)
1, 2, 12, 26
,
AD168A/FC2243 (LP11002)
1, 2, 12, 26
,
FCA2214/281541−B21 (QLA2340)
29, 38
,
FCA2214DC/321835−B21 (QLA2342)
29, 38
;
QLogic: QLA2200F−EMC
29, 41
,
QLA2310F−E−SP
29, 38, 39
, QLA2340−E−SP
29,
38, 39
, QLA2342−E−SP
29, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
184 HPQ Proliant DL580: (G4), (G5) VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 12, 26, 31
, LP11002−E
1,
2, 12, 26, 31
, LP1150−E
1, 2, 12, 26, 31
;
HPQ: AB429A/FC1143 (QLA2460)
12, 29, 31, 32
,
AE369A/FC1243 (QLA2462)
12, 29, 31, 32
;
QLogic: QLA2460−E−SP
12, 29, 31, 32
,
QLA2462−E−SP
12, 29, 31, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
185 HPQ Proliant DL380: (G4), (G5) VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E
1, 2, 12, 26
, LP11002−E
1, 2,
12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
186 Fujitsu Siemens Primergy TX200:
S3, S4;
HPQ Proliant: DL380 (G5), DL580
(G4), DL580 (G5)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
Emulex: LPe11002−E
1, 2, 12, 26
, LPe1150−E
1, 2,
12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
187 HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)
33
,
(G4), (G5);
HPQ Proliant ML370 (G4)
33
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
HPQ: AE311A/FC1142SR (QLE2460)
12, 29, 32
,
AE312A/FC1242SR (QLE2462)
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
188 Fujitsu Siemens Primergy TX200
S4;
HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)
33
,
(G4), (G5);
HPQ Proliant ML370 (G4)
33
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI, PCI
Express,
PCI−X
QLogic: QLE2460−E−SP
12, 29, 32
,
QLE2462−E−SP
12, 29, 32
, QLE2560−E−SP
12, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
189 HPQ Proliant: DL380 (G4), DL580
(G3)
33
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI,
PCI−X
Emulex LP1050Ex−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
190 HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)
33
, DL580
(G3)
33
, DL585, ML370 (G3)
33
;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI,
PCI−X
Emulex LP8000−EMC
26, 37, 42
;
QLogic: QLA2200F−EMC
29, 41
,
QLA2310F−E−SP
29, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150
03/04/2009 872 CLARiiON AX150