VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
99 IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7141)
105
, x3850M2
(7233, 7234)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
IBM: 39R6525 (QLE2460)
12, 29, 32
, 39R6527
(QLE2462)
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
100 IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
IBM: 42C2069 (LPe11000)
1, 2, 12, 26
, 42C2071
(LPe11002)
1, 2, 12, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
101 NEC Express 5800: 120Bb−6,
120Bb−d6, 120Bb−m6,
140Ba−10, B140a−T
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
NEC N8403−018 (LPe1105)
12, 26, 45, 77
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
102 NEC Express 5800 140Rf−4 VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
NEC: N8190−120 (LP1050)
2, 26, 35, 61
,
N8190−127 (LPe1150)
2, 26, 45, 62
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
103 Fujitsu Siemens Primergy RX300
S3;
Sun Sun Blade Server Module:
X6240, X6440, X6450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
QLogic QLA2340−E−SP
29, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
104 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
Fujitsu Siemens Primergy RX300
S4;
HPQ Proliant DL785 (G5);
Sun Sun Blade Server Module:
X6240, X6440, X6450;
Sun Sun Fire: X2200−M2, X4140,
X4150, X4240, X4250, X4440,
X4450
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
QLogic QLE2560−E−SP
12, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
105 Dell PowerEdge 1950;
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
QLogic: QLE2360−E−SP
12, 29, 50
,
QLE2362−E−SP
12, 29, 50
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
106 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193),
x3455 (7940)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
QLogic: QLE2460−E−SP
12, 29, 32, 59
,
QLE2462−E−SP
12, 29, 59
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
107 Fujitsu Siemens Primergy RX300
S4;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7141)
105
, x3850M2
(7233, 7234)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
QLogic: QLE2460−E−SP
12, 29, 32
,
QLE2462−E−SP
12, 29, 32
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
108 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440, X8450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
Sun SG−XPCIE2FC−EB4−Z: (LPem11002)
2, 12,
53, 54
, (LPem11002)
2, 12, 53, 55, 56
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
47
See
46
109 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440, X8450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
Sun SG−XPCIE2FC−EB4−Z: (LPem11002)
2, 12,
53, 57
, (LPem11002)
2, 12, 58
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
110 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
Sun SG−XPCIE2FC−QB4−Z: (QEM2462)
12, 32,
92
, (QEM2462)
12, 59, 93
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
47
See
46
111 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express
Sun SG−XPCIE2FC−QB4−Z: (QEM2462)
12, 59,
94
, (QEM2462)
12, 95, 96
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
112 IBM xSeries x3755: (7163),
(8877)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express,
PCI−X
Emulex LP10000−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
113 Dell PowerEdge: 2850, 6850;
HPQ Proliant: DL385 (G2), DL585
(G2);
IBM xSeries: x3550 (7978), x3655
(7943), x3800/x260 (8866),
x3850/x366 (8864)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express,
PCI−X
Emulex LP10000ExDC−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
114 HPQ Proliant: ML370 (G5)
33
,
ML570 (G4)
33
;
IBM xSeries x3755: (7163),
(8877)
VMware ESX Server
3.5
6, 7, 8, 9, 10, 28
PCI
Express,
PCI−X
Emulex LP1050−E
2, 12, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150