EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
VMware ESX Server
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
31 Dell PowerEdge 1955 VMware ESX Server
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
Dell 2342M
21, 38
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
32 HPQ Proliant: DL380 (G5), DL580
(G4)
VMware ESX Server
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
Emulex LPe1150−E
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
33 HPQ Proliant DL380: (G3), (G4);
HPQ Proliant: DL385, DL580
(G2)
33
, DL580 (G3)
33
, ML370
(G3)
33
, ML370 (G4)
33
VMware ESX Server
3.0
4, 5, 6, 7, 8, 9, 10, 40
PCI,
PCI−X
HPQ AD167A/FC2143 (LP1150)
1, 2, 11, 12
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
34 HPQ Proliant DL380 (G3) VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI Emulex: LP1050−E
2, 23, 44
, LP982−E
2, 23, 34, 44
;
QLogic QLA2340−E−SP
21, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
35 Fujitsu Siemens Primergy
BX660
73
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI Fujitsu Siemens BX600−FC22Q
12, 21, 52, 72
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
36 Dell PowerEdge: 1950, 6850;
Fujitsu Siemens Primergy RX300
S3
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express
Emulex LP1050Ex−E
2, 12, 23, 44
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
37 Dell PowerEdge 1950 VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express
Emulex: LP1050−E
2, 23, 44
, LP982−E
2, 23, 34, 44
;
QLogic: QLA2340−E−SP
21, 39, 52
,
QLE2360−E−SP
12, 21, 50
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
38 Fujitsu Siemens Primergy RX300
S3
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express
QLogic QLA2340−E−SP
21, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
39 Dell PowerEdge 6850 VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express
QLogic QLE2360−E−SP
12, 21
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
40 Dell PowerEdge 6850 VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
Dell 2362M
21, 66, 67
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
41 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850;
Fujitsu Siemens Primergy TX300
S3;
HPQ Proliant DL360 (G5);
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)
71
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
Emulex LP1050Ex−E
2, 12, 23, 44
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
42 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850;
HPQ Proliant DL360 (G5);
IBM xSeries: x336 (8837)
71
,
x3550 (7978), x3650 (7979);
NEC Express 5800 140He
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
Emulex: LP1050−E
2, 23, 44
, LP982−E
2, 23, 34, 44
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
43 HPQ Proliant DL360 (G5) VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)
12, 32, 43
;
QLogic QLA2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
44 HPQ Proliant: DL360 (G5),
ML370 (G5)
33
, ML570 (G3)
33
,
ML570 (G4)
33
;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
HPQ AE311A/FC1142SR (QLE2460)
12, 32, 49
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
45 IBM xSeries: x3550 (7978), x3650
(7979)
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
IBM 24P0960 (QLA2340)
21, 38, 63
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
46 NEC Express 5800: 120Li,
120Rg−1, 120Ri−2, 140He
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
NEC N8190−120 (LP1050)
2, 35, 44, 61
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
47 Fujitsu Siemens Primergy TX300
S3;
HPQ Proliant DL360 (G5);
IBM xSeries: x336 (8837)
71
, x346
(8840), x3550 (7978), x3650
(7979)
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
QLogic QLA2340−E−SP
21, 38, 39
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
48 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
QLogic QLA2340−E−SP
21, 39, 52
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
49 Dell PowerEdge: 1850, 2850,
2900, 2950;
IBM eServer 326m (Model 7969)
VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
QLogic QLE2360−E−SP
12, 21, 50
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
50 IBM eServer 326m (Model 7969) VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
QLogic QLE2460−E−SP
12, 32, 43
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
51 Dell PowerEdge: 2900, 2950 VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
QLogic QLE2460−E−SP
12, 32, 43, 59
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
52 Dell PowerEdge 1855 VMware ESX Server
3.0
5, 6, 7, 8, 9, 10, 40
PCI−X Dell 2342M
21, 38
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
13, 14
CLARiiON AX150