Red Hat RHEL [x86_64]
No. Host System
Operating
System Host Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
1192 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]:
4.0 U4
AS/ES
9,
30
, 4.5
AS/ES
9, 56
PCI
Express,
PCI−X
Emulex LPe111−E
3, 12, 14,
31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1193 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950
Red Hat
RHEL
[x86_64]:
4.0 U4
AS/ES
9,
30
, 4.5
AS/ES
9, 56
PCI
Express,
PCI−X
Emulex LPe111−E
3, 12, 31,
36, 37
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1194 Acer Altos R710;
Anders & Rodewyk Ariane: 145, 245;
Aquarius AquaServer TD322;
BGM Elitas: SR510, SR710;
Compusys ProManaged: SR1400JR2, SR2400JR2;
Digital Henge Revo: JS1400, JS2400;
Gateway: E−9415R, E−9515R;
Intel: SR1400/SE7520JR2, SR2400/SE7520JR2;
MPC NetFRAME: 1720, 2720;
MaxData Platinum: 1500 IR M5, 2200 IR M5;
Nanobay: JR1400, JR2400;
Ockam OS−7000;
PowerLeader: PR1700, PR1700 G2, PR2700, PR2700
G2;
R−Style MARSHALL: NP281r, NP282r;
Samsung ZSS150;
Verari RM2205;
Wortmann TERRA AQUA: 6200, 6300, 6500
Red Hat
RHEL
[x86_64]:
4.0 U4
AS/ES
9,
30
, 4.5
AS/ES
9, 56
PCI
Express,
PCI−X
106
Emulex: LP101−E
3, 12, 15,
31
, LP1050−E
12, 15, 31
,
LP982−E
15, 16, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1195 Dell PowerEdge 1855 Red Hat
RHEL
[x86_64]:
4.0 U4
AS/ES
9,
30
, 4.5
AS/ES
9, 56
PCI−X Dell LPe1105−M
3, 31, 37, 64
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
1196 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4, SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T, HR−6850,
HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Red Hat
RHEL
[x86_64]:
4.0 U4
AS/ES
9,
30
, 4.5
AS/ES
9, 56
PCI−X Emulex LP101−E
12, 15, 31
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 732 CLARiiON AX150