EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Microsoft Windows 2003 [x64]
No. Host System Operating System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
32 IBM xSeries: x3650 (7979), x3655 (7985), x3755
(8877)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express
QLogic
QLE2360−E−SP
4, 7, 17,
81
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
1
33 HPQ Proliant: DL360 (G5), DL365, DL385 (G2),
DL385 (G5), DL580 (G5), DL585 (G2), ML350
(G5)
28
, ML370 (G5)
28
, ML570 (G4)
28
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LP1050−E
4, 21,
22, 23, 24
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
13
34 Dell PowerEdge: 1900, 2900, 2950 Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LP1050Ex−E
4,
19, 21, 22, 23, 24
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
13
35 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585
(G5);
IBM xSeries: x3655 (7943), x3755 (7163)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LP1150−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
13
36 IBM xSeries: x3650 (7979), x3655 (7943), x3655
(7985)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LP982−E
4, 21,
22, 24, 29
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 32
See
13
37 IBM xSeries x346 (8840)
53
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LPe111−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
13
38 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970;
HPQ Proliant: DL365, DL385 (G2), DL580 (G5),
DL585 (G2);
IBM xSeries: x346 (8840)
53
, x3655 (7943), x3655
(7985)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LPe1150−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
13
39 HPQ Proliant DL385 (G5);
IBM xSeries x3755 (7163)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
Emulex LPe1150−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
13
40 HPQ Proliant: DL365, DL385 (G2), DL580 (G5) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
HPQ
A8002A/FC2142SR
(LPe1150)
19, 21, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
3, 25
41 HPQ Proliant: DL360 (G5), DL365, DL385 (G2),
DL580 (G5), DL585 (G2), ML350 (G5)
28
, ML370
(G5)
28
, ML570 (G4)
28
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
HPQ AD167A/FC2143
(LP1150)
19, 21, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
3
42 IBM xSeries x3655 (7943) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
QLogic
QLE2360−E−SP
4, 7, 17,
81
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 25
See
1
43 IBM xSeries x3755 (7163) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
QLogic
QLE2360−E−SP
4, 7, 17,
81
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
1
44 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850;
HPQ Proliant ML570 (G3)
28
;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries x3950/x3950E/x460 (8872, 8874)
38
;
Sun Sun Fire: V20z, V40z, X4100, X4200
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI−X Emulex LP1050−E
4, 21,
22, 23, 24
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
13
45 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5,
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Sun Sun Fire: X4100, X4200;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI−X Emulex LP1150−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3, 32
See
13
46 HPQ Proliant: DL360 (G5), DL365, DL380 (G5),
DL385 (G2), DL585 (G2), ML570 (G3)
28
;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3650 (7979), x3655 (7985),
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V20z, V40z
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2
PCI−X Emulex LP1150−E
4, 19,
21, 22, 23, 26
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2, 3
See
13
CLARiiON AX150
03/04/2009 82 CLARiiON AX150