SuSE SLES [32−Bit]
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
134 HPQ Proliant: BL260c G5 (quad core
processor)
82
, BL2x220c G5 (quad core
processor)
82
, BL460c (dual core
processor)
82
, BL460c (quad core
processor)
82
, BL465c (dual core
processor)
82
, BL465c G5 (quad core
processor)
82
, BL480c (dual core
processor)
82
, BL480c (quad core
processor)
82
, BL495c G5 (quad core
processor), BL680c (G5)
82
, BL685c (dual
core processor)
82
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
HPQ QLogic QMH2462 4Gb FC HBA for HP
c−Class Bladesystem (403619−B21)
35, 83
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
135 IBM xSeries x3850M2: (7141)
38
, (7233,
7234);
IBM xSeries x3950M2: (7141)
38
, (7233, 7234)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
IBM: 42D0485 (LPe12000)
11, 12, 13, 88, 89
,
42D0494 (LPe12002)
11, 12, 13, 40, 87
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
22, 74
See
55
136 IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
IBM: 42D0485 (LPe12000)
11, 12, 13, 88, 89
,
42D0494 (LPe12002)
11, 12, 13, 40, 87
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
22
137 IBM xSeries x3455: (7940), (7984) SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
IBM: 42D0501 (QLE2560)
2, 12, 35, 58
, 42D0510
(QLE2562)
2, 12, 35, 57
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
22
138 IBM xSeries x3950M2 (7141)
38
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
IBM: 42D0501 (QLE2560)
2, 12, 35, 58
, 42D0510
(QLE2562)
2, 12, 35, 57
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
22
See
55
139 IBM xSeries: x3350 (4192,4193), x3850M2
(7141)
38
, x3850M2 (7233, 7234), x3950M2
(7233, 7234)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
IBM: 42D0501 (QLE2560)
2, 12, 35, 58
, 42D0510
(QLE2562)
2, 12, 35, 57
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
22, 74
See
55
140 Dell PowerEdge: R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries x3950M2 (7141)
38
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 12, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
55
141 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
HPQ Proliant DL785 (G5);
IBM xSeries x3850M2: (7141)
38
, (7233,
7234);
IBM xSeries x3950M2 (7233, 7234);
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 12, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
74
See
55
142 Dell PowerEdge: R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984), x3850M2 (7233, 7234),
x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150,
X4240, X4440, X4450
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
143 HPQ Proliant DL785 (G5) SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
42
144 IBM xSeries: x3850M2 (7141)
38
, x3950M2
(7141)
38
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
31
145 Sun Sun Fire X4250 SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2460−E−SP
2, 35
;
Sun: SG−XPCIE1FC−QF4 (QLE2460)
35, 63
,
SG−XPCIE2FC−QF4 (QLE2462)
35, 63
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
31, 50,
51
146 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic QLE2462−E−SP
2, 12, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
55
147 Dell PowerEdge: R805, R900, R905 SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic: QLE220−E−SP
2, 12, 35, 49
,
QLE2560−E−SP
2, 12, 35
, QLE2562−E−SP
2, 12, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y See
55
148 IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic: QLE220−E−SP
2, 12, 35
,
QLE2360−E−SP
35, 64, 65
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
149 Dell PowerEdge: 1950, 1950 III, 2900 III,
2950 III, 2970, 6800, 6850, R805, R900,
R905;
IBM xSeries x3455 (7940)
SuSE
SLES
[32−Bit] 10
SP2
4, 5, 7,
8, 9, 33, 34
PCI
Express
QLogic: QLE2560−E−SP
2, 12, 35
,
QLE2562−E−SP
2, 12, 35
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 755 CLARiiON AX150