EMC AX150 Series Network Card User Manual


  Open as PDF
of 1015
 
Novell Netware
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot
22 Dell PowerEdge: 2900, 2950;
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864)
Novell Netware
6.5: SP4
1
,
SP4a
1
, SP5
1
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP
2, 26,
27
FC−AL,
FC−SW
EMC
CLARiiON
AX150
3, 4,
5, 6, 7, 8, 9,
10, 11, 12,
13, 14, 15
Y
23 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650;
Fujitsu Siemens Primergy: F250
22
, RX200, RX300, RX300 S2, TX150,
TX200, TX300;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760, DL760 (G2), ML570
(G2)
18
;
IBM xSeries: x235, x255, x336 (8837)
19
, x346 (8840), x3850/x366 (8863)
20
;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
Novell Netware
6.5: SP4a
1
,
SP5
1
PCI−X QLogic
QLA2340−E−SP
2, 16
FC−AL,
FC−SW
EMC
CLARiiON
AX150
3, 4,
5, 6, 7, 8, 9,
10, 11, 12,
13, 14, 15
Y
1. Novell OES is supported on this kernel.
2. SNIA HBA API Supported.
3. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
4. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
5. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After
Abend". When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
6. Remote boot not supported with PERC controllers enabled in system BIOS.
7. No MirrorView or SnapView used on boot LUNs.
8. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
9. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
10. Edit config.sys with the following: Files=100, Buffers=99
11. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any
found in previous boot documentation.
12. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
13. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
14. Novell Storage Services supported.
15. Supports eight (8) hosts per array.
16. Driver Version 6.90d Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
19. Certain HBA models may be too large to fit into this server's PCI or PCI−X slots. A low−profile HBA may be required. Consult your server owner's guide before
purchasing HBAs for this server.
20. Support for 4GB fibre channel HBAs requires an IBM SPORE to be submitted to IBM with a request of system BIOS 56A.
21. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
22. Must use standard PCI 32bit/33MHz slot for SCSI
23. PowerPath is not supported in conjunction with host−based mirroring.
24. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
25. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. BIOS 1.24
27. Driver Version 6.90m
28. This server is equipped with plastic shielding around the PCI slots. Since the PCI slots are 32−bit, this shielding prohibits 64−bit HBAs from properly seating in the PCI slots. To
accomodate 64−bit HBAs, this shielding must be removed, or modified to allow the 64−bit HBA to fully seat in the 32−bit slots.
29. Includes both Pentium PRO and XEON models
30. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
31. BIOS 1.52 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
32. Driver Version 6.90m Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. BIOS 1.24 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
Oracle Enterprise Linux [32−Bit]
Oracle Enterprise Linux [32−Bit]
No. Host System
Operating
System
Host
Bus Host Bus Adapter Topology
Storage
Array
External
Boot Comments
1 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 2550
34
,
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450;
HPQ Proliant: DL320, DL360, DL360 (G2), DL380, DL380
(G2), DL380 (G3), DL580 (G2)
24
, DL580
24
, ML350 (G2)
24
,
ML350 (G3)
24
, ML350
24
, ML370 (G2)
24
, ML370
24
, ML530
(G2)
24
, ML530 (G3)
24
, ML530
24
, ML570
24
, ML750
24
Oracle
Enterprise
Linux
[32−Bit] 4
U6
4, 64
PCI Emulex LP101−E
8, 9, 20, 67
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
2 HPQ Proliant: DL320, DL360, DL360 (G2), DL580
24
,
ML350 (G2)
24
, ML350 (G3)
24
, ML350
24
, ML370 (G2)
24
,
ML370
24
, ML530 (G2)
24
, ML530 (G3)
24
, ML530
24
,
ML570
24
, ML750
24
Oracle
Enterprise
Linux
[32−Bit] 4
U6
4, 64
PCI Emulex: LP1050−E
8, 20, 67
,
LP982−E
7, 20, 67
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
3 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 2550
34
,
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450
Oracle
Enterprise
Linux
[32−Bit] 4
U6
4, 64
PCI Emulex: LP1050−E
8, 9, 20, 67
,
LP982−E
7, 9, 20, 67
;
QLogic QLA2340−E−SP
2, 9, 63
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
4 HPQ Proliant: DL320, DL360, DL360 (G2), DL380, DL380
(G2), DL380 (G3), DL580 (G2)
24
, DL580
24
, ML350 (G2)
24
,
ML350 (G3)
24
, ML350
24
, ML370 (G2)
24
, ML370
24
, ML530
(G2)
24
, ML530 (G3)
24
, ML530
24
, ML570
24
, ML750
24
Oracle
Enterprise
Linux
[32−Bit] 4
U6
4, 64
PCI QLogic QLA2340−E−SP
2, 63
FC−AL,
FC−SW
EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 281 CLARiiON AX150