20.4 Voltage supply
Input 3-pole XLR- Flange (male), lockable
Voltage Supply 24 V dc (+/- 5 %) / 3 A
[For ac operation {230/120 V} dc supply by options SL10, SL5 (both for rack
mounting only) UPS 01 T, or equivalent power supply]
20.4.1 Electrical Safety
Over-voltage category II
Pollution degree 2
Safety Class 2 ( )
all I/O´s SELV voltage
optically isolated to electrical supply
20.4.2 Power Supplys [UPS 01 T (Universal Power Supply) / SL10 / SL5]
Input (UPS/SL10/
SL5
) plug / terminal strips /
terminal strips
Nominal voltage 230 / 120 V ac, 50 / 60 Hz
Input voltage 196–264 V ac and 93–132 V ac, 47-63 Hz
UPS / SL10 or SL5 with autoranging / manual switch
Input power
UPS or SL5 /
SL10
max. 240 VA /
max. 700 VA
Fuses UPS (internal) T 3.15A/250V (2 pcs.)
Output 3-poliger XLR- Flange (female) (UPS) /
terminal strips (SL10 / SL5)
Output voltage 24 V dc
UPS / SL10 /
SL5
max. 5.0 A / max. 10.0 A /
max. 5.0 A
Output power
UPS / SL10 /
SL5
max. 120 VA / max. 240 VA /
max. 120 VA
Dimensions
UPS Rack module 19" 3 HU, 21 DU
Installation depth (with plug / cable) min. 400 mm
UPS table-top module see Fig. 20-11
SL5 (mountable on DIN supporting rails TS35) 125 x 65 x 103 mm (HxWxD),
see Fig. 20-9 and 20-10
SL10 (mountable on DIN supporting rails TS35) 125 x 122 x 103 mm (HxWxD),
see Fig. 20-8 and 20-10