Emerson ETC00303 Printer Accessories User Manual


 
FRONT PANEL PROGRAM
8 - 6
ETC00303(1) BINOS E e (2.0) 11/00
Rosemount Analytical
FUNCTION KEYS
During zero gas adjustment the deviation of the actual value is compared with the max.
deviation (threshold value) from the file ”BinosOEM.INI”.
The menu provides the ability to change the
threshold value from 1 % of full scale up to the
maximum threshold value.
If the threshold value is exceeded, an alarm message will appear offering the option to stop the
zero gas calibration procedure.
F6 Span gas calib.:
To protect this function against unautho-
rized access, a password (access code)
option is available.
If no password has been set you will be
asked to define one (this is not required).
ATTENTION: Before starting span gas adjustment, ensure that span gas with
the desired concentration is available!
Within this dialog box you can also
change the existing access code.
If a password is defined, it can be
changed but not eliminated entirely.
The ”Span gas calib.” function key starts the dialog for span gas calibration.