Epson SR-600 Cash Register User Manual


 
Rev.A Peripherals/Option Installation 6-35
Developer's Guide SR-600
Confidential
Track2Start=2S
Track2End=2E
Track3Start=3S
Track3End=3E
JIS2Start=JS
JIS2End=JE
In the [General] section, entry lines which basically have an influence on the utility as a whole
are described.
“On” can be selected for the IgnoreCommands so that reading or writing to the Keyboard and
MSR setting is disabled.
System Param xx is described in the case where data are written to the system variable area.
Variable offset and data are separated by a ",". These two are byte widths, and they can be
specified in the form of decimal numbers, hexadecimal numbers and characters. In the case of
decimal numbers, they are described as is, but in the case of hexadecimal numbers, it is
necessary to add a "&" at the top of the number while in the case of characters, it is necessary to
add a "$" at the top of the number. Multiple System Param xx items can be declared. Each of
these parameters is described in order with xx being a decimal number identifying each
parameter, beginning with 00. The maximum number of parameters that can be described is 99.
In the [MSR] section, entry lines related to the MSR are described.
"On" or "Off" can be specified for Beep. If "On" is specified, it beeps during MSR reading, and
when "Off" is specified, it does not beep.
Selecting US, JP, FR, GR or SP can be specified in Code Type. The key input data generated
during MSR reading complies with the keyboard arrangement of the country specified.
"1," "2" or "3" can be specified in Valid Tracks. If "1" is specified, Track 1 is read, if "2" is specified,
Track 2 is read and if "3" is specified, Track 3 is read. Multiple tracks can be specified, in which
case they are separated by a ",".
Code Definition xx is described in the case that a unique character is generated during MSR
reading. Information is input in the order of character code, then key No., then information on
the keys which are pressed simultaneously, with each of the items separated by a ",". If it is not
necessary, the information on the keys which are pressed simultaneously can be omitted. The
character code and key No. are in the same format as in System Param xx. Simultaneously
pressed key information can be specified with the Shift, Ctrl, Alt or AltGr keys. It is also possible
to describe multiple Code Definition xx items. In such a case, each code definition is described in
order with xx being the decimal number identifying each code, beginning with 00. The
maximum number of code definitions that can be described is 99.