Memory Address Error at ... Indicates a memory address error at a specific location.
You can use this location along with the memory map for your system to find
and replace the bad memory chips.
Memory parity Error at ... Indicates a memory parity error at a specific location.
You can use this location along with the memory map for your system to find
and replace the bad memory chips.
MEMORY SIZE HAS CHANGED
SINCE LAST BOOT
Memory has been added or removed since the last boot.
In EISA mode use Configuration Utility to reconfigure the memory
configuration. In ISA mode enter Setup and enter the new memory size in the
memory fields.
Memory Verify Error at ... Indicates an error verifying a value already written to memory.
Use the location along with your system's memory map to locate the bad
chip.
OFFENDING ADDRESS NOT FOUND This message is used in conjunction with the I/O CHANNEL CHECK and RAM
PARITY ERROR messages when the segment that has caused the problem
cannot be isolated.
OFFENDING SEGMENT: This message is used in conjunction with the I/O CHANNEL CHECK and RAM
PARITY ERROR messages when the segment that has caused the problem
has been isolated.
PRESS A KEY TO REBOOT This will be displayed at the bottom screen when an error occurs that
requires you to reboot.
Press any key and the system will reboot.
PRESS F1 TO DISABLE NMI, F2 TO
REBOOT
When BIOS detects a Non-maskable Interrupt condition during boot, this will
allow you to disable the NMI and continue to boot, or you can reboot the
system with the NMI enabled.
RAM PARITY ERROR - CHECKING
FOR SEGMENT ...
Indicates a parity error in Random Access Memory.
Should Be Empty But EISA Board
Found
PLEASE RUN EISA CONFIGURATION
UTILITY
A valid board ID was found in a slot that was configured as having no board
ID.
NOTE; When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.
Should Have EISA Board But Not
Found
PLEASE RUN EISA CONFIGURATION
UTILITY
The board installed is not responding to the ID request, or no board ID has
been found in the indicated slot.
NOTE: When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.
Slot Not Empty Indicates that a slot designated as empty by the EISA Configuration Utility
actually contains a board.
NOTE: When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.
SYSTEM HALTED, (CTRL-ALT-DEL) TO
REBOOT ...
Indicates the present boot attempt has been aborted and the system must
be rebooted.
Press and hold down the CTRL and ALT keys and press DEL.
Wrong Board In Slot
PLEASE RUN EISA CONFIGURATION
UTILITY
The board ID does not match the ID stored in the EISA non-volatile memory.
NOTE: When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.
FLOPPY DISK(S) fail (80) Unable to reset floppy subsystem.
FLOPPY DISK(S) fail (40) Floppy Type dismatch.
Table 3-8 POST Messages (Continued)
Message Description