Epson SR-600 Cash Register User Manual


 
Rev.A OS and Driver Setup 2-15
Developer's Guide SR-600
Confidential
Initial Setup
Follow the steps below to set up the system.
1. Turn on the power, and boot the system from the pre-installation HDD.
Windows NT Setup (GUI Mode Setup) starts.
2. Select the necessary options and install. Follow the instructions of the GUI Mode Setup.
3. Select LCD Panel Type.
4. Select Service Pack Install.
Reboot the system if Service Pack 4 or the advanced version is installed.
5. Select Windows NT from the Boot Loader Menu, and start Windows NT.
6. Log on to the system using the Administrator.
The installation of the IE4.01 and MDAC2.0 starts.(Entry is not required during the
installation of the IE4.01 and MDAC2.0.)
The system will automatically reboot after the installation is completed. The log-on operation
will be normal from the next startup of Windows NT.
CAUTION:
VGA Mode setup is executed.
The keyboard must be connected before starting the setup as the touch panel cannot
be used until all the settings are completed and the system is rebooted. Even when the
touch panel cannot be used, the keyboard must be used to log on to Windows NT for
startup of the log-on process by using the CTRL+ALT+DEL keys and for the user
authentication.
If log-on utility is installed, Keyboard connection can be logged on with log-on utility
and is not necessary.
Service Pack Installation
Start up the following dialogue box for selecting the service pack to be installed in the setup
process of Windows NT.
The style of the dialogue box should be such that no system menu is included and the
size of the window is fixed.
Attempting to exit out of the dialogue box by pressing the
AL
T+
F4
keys will be ignored.
In the startup process of this dialog box, the Service Pack is not selected.