Back Plate
1 Remove the Stapling Unit Assembly (see Figure 6-91).
2 Remove the Scan Bar by carefully pressing the tab on the scan bar
backwards and downwards through the hole of the Stapling Bed (see
Figure 6-92) with a flat-tip screwdriver, then lift the bar.
3 Remove the torx screw joining the Back Plate with the Stapling Unit (see
Figure 6-93, callout 2).
4 Release the ground cable that is connected to the Back Plate (see Figure
6-93, callout 1).
To Reinstall
Caution
Keep the Top Cover Assembly open while reconnecting the cables. Cable
damage could occur the next time the cover is opened if the cables are
reinstalled too tightly.
Do not overtighten the screws when replacing the Back Plate.
Caution
Do not touch the metallic plate edges.