STOPP Command
The STOPP command has the form:
STOPP
This command causes an active PING sequence to stop at its next iteration and to print
the results of the terminated test. It is used to terminate a long running PING sequence.
STOPT Command
The STOPT command has the form:
STOPT
This command causes an active TEST sequence to stop at its next iteration and to print
the results of the terminated test. It is used to terminate a long running test before its
completion.
A typical STOPT command is shown below:
= stopt
Test stopped by operator
= Page 1 of 1
<<< Test Results >>>
Command: test <<0800190100fb>> 100H 32H 0H NULL
Init node: <<08001901001f>> Frames sent : 87H Nodes responding : 1H
Responding nodes Response recd Response w/err No Response
<<0800190100fb>> 87H 0H 0H