GE GFK-1004B Network Router User Manual


 
6
6-33
GFK-1004B
Chapter 6 Troubleshooting
Table 6-10. Exception Log Event Codes - Continued
Log Event
Code Possible Cause and Resolution
Event “1c”
Channel API
events
(Continued)
7 “LAN system-software fault: aborted assoc. & resuming”
Internal error: An attempt to set a timer failed. Entry 3 contains the aborted
channel number.
Entry 4 contains the high word of the time value used in the attempt to set
the timer.
Entry 5 contains the low word of the time value used in the attempt to set
the timer.
a “LAN system-software fault: aborted assoc. & resuming”
Internal error: A channel machine’s write PDU submachine was accessed in
its IDLE state. Entry 3 identifies the channel number of the aborted channel
machine.
b “Bad remote application request; discarded request”
An SRTP PDU arrived to the Channel API having an unexpected value in its
version field. This suggests that the remote SRTP endpoint may be running
software that is incompatible with your version of the Channel API. Entry 3
contains the aborted channel number. Entry 4 contains the version number
found in the arrived PDU. Entry 5 contains the version number expected by
the Channel API.
c “Bad remote application request; discarded request”
An SRTP PDU arrived with a non-zero data field; however, the PDU is of the
type where data is not allowed. Entry 3 contains the aborted channel
number. Entry 4 contains the PDU type code.
Valid PDU type codes are:
0 Connect Request
1 Connect Response
2 Data Request
3 Data Response
4 Unconfirmed Request
5 Error Request
6 Destinations Request
7 Destinations Response
8 Session Request
Entry 5 contains the low word of the data field.
d “Bad remote application request; discarded request”
An SRTP PDU arrived with a PDU type code that the Channel API does not
support. At present, the Channel API only supports the arrival of the
following PDU types: Connect Response, Data Response, and Error Request.
Entry 3 contains the aborted channel number. Entry 4 contains the
offending PDU type code.
e “LAN data memor y exhausted-check parms; resuming”
Internal error: An attempt to allocate a buffer failed.
11 “LAN system-software fault; resuming”
The Channel API software was accessed by other internal software, but the
Channel API has not yet been initialized.
12 “LAN system-software fault; resuming”
Internal error: An attempt to find the channel machine corresponding to a
given TCP connection has failed. Entry 3 contains the TCP endpoint
identifier of the particular TCP connection.