GE GFK-1004B Network Router User Manual


 
5
5-43
GFK-1004B
Chapter 5 The Station Manager
A typical TEST command is shown below:
Page 1 of 1
= test 0800190100fb 100H
Test initiated
=
<<< Test Results >>>
Command: test <<08001901001f>> 100H 32H 1H ALT
Init node: <<08001901001f>> Frames sent : 100H Nodes responding : 1H
Responding nodes Response recd Response w/err No Response
<<0800190100fb>> 100H 0H 0H
TIME Command
The TIME command has the form:
TIME
This command causes the current system time to be displayed. This time is used in gen-
erating time stamps for messages which require them. This time is also used as a time
stamp for events in the exception log displayed by the LOG command. The initial value
of the time on restart, power up, or load is read from the local PLC CPU. If this is not
available, it is set to 00:00:00.0 (midnight). Time values are based on a 24 hour clock. The
Modify command CHTIME is used to change the time value.
A typical TIME command is shown below:
> time
Time = 15:46:02.3
TRACE Command
The TRACE command has the form:
TRACE {<task(s)> [<minutes> [<len_ref>]] | !}
where <task(s)> is one or more task identifier letters from Table 5–3 or “z” to add PDU
trace.
<minutes>is an optional parameter that specifies how long TRACE will remain active.
Default is 10 minutes. This parameter is a character string that specifies an integer which
can be 0, or a value from 1 to 32767. If 0 is specified then time out is not enforced. Any
non-zero value specifies the duration in minutes after which the trace activity will auto-
matically cease. Login will be maintained (automatic logout will be inhibited) until after
the trace has terminated.
<len_ref> is an optional parameter that limits the amount of PDU (z) data to be dis-
played. The PDU display format is a character string that specifies an integer value
ranging from 1 to 32767. If omitted from the command line, the value 48 will be substi-
tuted. This parameter provides the flexibility to view the PDU in its entirety or just a
portion of it. Since each line of display consists of 16 bytes, and, if truncating of the PDU
does take place (always at the end of a line and trailed by ’...’ on the next line), the actual
number of bytes displayed will be rounded up to the next multiple of 16 from
<len_ref>. There is, of course, a performance penalty for displaying large PDU’s when
they occur frequently.