HP (Hewlett-Packard) 9055 Printer User Manual


 
156 MFP disassembly/assembly ENWW
Removing and reinstalling the
separation claws and separation
claw solenoid
CAUTION Be sure the power cord has
been unplugged from the
wall outlet.
Take care not to damage
the drum when removing
the separation claws.
Note the orientation and
position of the separation
claws when reinstalling
them.
CAUTION Do not touch the cleaning
blade and drum with bare
hands.
Procedure
1 Remove the drum unit from the MFP.
2 Remove the drum.
3 Remove the connector (CN363) and
separation swing spring.
4 Remove two screws and detach the
separation guide plate assembly.
5 Remove the snap ring, slide the shaft, and
remove the three separation claws.
CAUTION Clean the shaft with drum
cleaner and a cleaning pad
when installing.
The separator claws
cannot move smoothly if
they are installed with toner
remaining on the shaft.
When installing, insert the
retaining ring between the
ribs.
After installing the
separation claws, check
that they move smoothly.
Connector (CN363)
Screws
Separation guide plate assembly
Separation swing spring