HP (Hewlett-Packard) 9055 Printer User Manual


 
214 MFP disassembly/assembly ENWW
9 Reinstall the above parts following the
removal steps in reverse.
CAUTION After installing the fusing
separation claw (upper),
move the upper claws with
your finger and check that
they return with the force of
the spring.
Removing and reinstalling the
fusing separation claw (lower)
unit and fusing separation claws
(lower)
Procedure
1 Remove the fuser.
2 Open the fuser (upper).
3 Remove two screws to detach the fusing
separation claw (lower) assembly.
4 Remove the three springs from the three
fusing separation claws (lower).
5 Slide the frame holding the fusing
separation claws (lower) and remove the
three claws.
6 Reinstall the above parts following the
removal steps in reverse.
CAUTION After installing the fusing
separation claw (lower),
check that the frame
moves smoothly.
Removing and reinstalling the
fusing upper roller
Procedure
1 Remove the fuser.
2 Remove the fuser front cover.
3 Remove the fusing separation claw
(upper) unit.
4 Open the fuser (top).
5 Remove the fusing heater lamps (L2, L3).
Fixing separation
claws (lower) (3)
Spring
Screws(2)
Frame
Fixing
separation claw
(lower) assembly