How to Use the Console
Clearing of Absolute Encoder
Only applicable to the system which uses absolute encoder. You can clear the alarm and multi-turn data of
the absolute encoder.
Clearing of absolute encoder starts
Clearing finishes
Error occurs
(
When non-applicable encoder is
)
connected
Clearing of absolute encoder 
completes
<Remarks>
Don't disconnect the console from the driver between to .
Should the connector is pulled out, insert it again and repeat the procedures from the beginning.
<Notice>
If an error code No. 40 is shown on the console immediately after purchase, clear the absolute encoder
through the console.
Press five time after pressing , to setup auxiliary function mode, 
then with , make a display to
Press to call for 
EXECUTION DISPLAY of
Then keep pressing until the display of Console (LED) 
changes to
“ ” increases by 
pressing (approx. 5sec) 
as the left fig. shows.
SELECTION display
When you have cleared the absolute encoder, press to return to .
A incremental encoder or any
unsupported encoder other than an
absolute encoder may be connected.
Reset the power supply and clear the
error.
Operation at SELECTION display