Panasonic A4P Series Power Supply User Manual


 
62
Parameter Setup
Standard default : < >
Servo
PrNo.
Setup
range
UnitTitle Function/Content
21 0 to 7
<1>
–Real time auto
tuning set up
You can set up the action mode of the real-time auto-gain tuning.
With higher setup such as 3 or 6, the driver respond quickly to the change
of the inertia during operation, however it might cause an unstable
operation. Use 1 or 4 for normal operation.For the vertical axis application,
use with the setup of 4 to 6.
When vibration occurs at gain switching, set up this to "7".
Setup value
0
<1>
2
3
4
5
6
7
Real-time
auto-gain tuning
Invalid
Normal mode
Vertical axis mode
No gain switching
Varying degree of 
load inertia in motion
Little change
Gradual change
Rapid change
Little change
Gradual change
Rapid change
Little change
24 0 to 2
<0>
–Vibration
suppression filter
switching selection
You can select the switching method when you use the vibration
suppression filter.
25 0 to 7
<0>
–Normal auto tuning
motion setup
You can set up the action pattern at the normal mode auto-gain tuning. 
e.g.) When the setup is 0, the motor turns 2 revolutions to CCW and 2
revolutions to CW.
Setup value
<0>
1
2
3
4
5
6
7
Number of revolution
2 [revolution]
1 [revolution]
Rotational direction
CCW CW
CW CCW
CCW CCW
CW CW
CCW CW
CW CCW
CCW CCW
CW CW
23 0 to 2
<1>
–Adaptive filter
mode
You can set up the action of the adaptive filter.
22 0 to 15
A to C-frame:
<4>
D to F-frame:
<1>
–Machine stiffness
at auto tuning
You can set up the machine stiffness in 16 steps while the real-time auto-
gain tuning is valid.
<Caution>
When you change the setup value rapidly, the gain changes rapidly as
well, and this may give impact to the machine. Increase the setup
gradually watching the movement of the machine.
low machine stiffness high
low servo gain high
low response high
SV.Pr22 0, 1- - - - - - - - - - - - 14, 15
Setup value
0
<1>
2
Content
Invalid
Valid
Hold
(holds the adaptive filter frequency when this setup is changed to 2.)
Setup value
<0>, 1
2
Content
No switching (both of 1st and 2nd are valid.)
You can switch with the position command direction.
CCW : 1st damping filter selection (SV.Pr2B, 2C).
CW : 2nd damping filter selection (SV.Pr2D, 2E).