Release of Automatic Gain Adjusting Function
SV.Pr2F
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1st notch frequency [Hz]
(invalid)
(invalid)
(invalid)
(invalid)
(invalid)
1482
1426
1372
1319
1269
1221
1174
1130
1087
1045
1005
967
930
895
861
828
796
SV.Pr2F
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
1st notch frequency [Hz]
766
737
709
682
656
631
607
584
562
540
520
500
481
462
445
428
412
396
381
366
352
339
SV.Pr2F
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
1st notch frequency [Hz]
326
314
302
290
279
269 (invalid when Pr22
>
=
15)
258 (invalid when Pr22
>
=
15)
248 (invalid when Pr22
>
=
15)
239 (invalid when Pr22
>
=
15)
230 (invalid when Pr22
>
=
15)
221 (invalid when Pr22
>
=
14)
213 (invalid when Pr22
>
=
14)
205 (invalid when Pr22
>
=
14)
197 (invalid when Pr22
>
=
14)
189 (invalid when Pr22
>
=
14)
182 (invalid when Pr22
>
=
13)
(invalid)
(invalid)
(invalid)
(invalid)
(invalid)
*Set up 1500 to SV.Pr1D (1st notch frequency) in case of “ invalid ” of the above table.
Outline
Cautions are described when you want to invalidate the real time auto-gain tuning of default or the adaptive filter.
Caution
Execute the release of the automatic adjusting functions while all action stop (Servo-OFF)
Invalidation of Real-Time Auto-Gain Tuning
You can stop the automatic calculation of SV.Pr20 (Inertial ratio) and invalidate the real-time auto-gain
tuning by setting up SV.Pr21 (Real time auto tuning set up) to 0.
Note that the calculation result of SV.Pr20 (Inertia ratio) will be held, and if this parameter becomes abnor-
mal value, use the normal mode auto-gain tuning or set up proper value manually obtained from formula or
calculation.
Invalidation of Adaptive Filter
When you set up SV.Pr23 (Adaptive filter mode) to 0, adaptive filter function which automatically follows the
load resonance will be invalidated.
If you invalidate the adaptive filter which have been working correctly, noise and vibration may occur due to
the effect of resonance which have been suppressed.
Therefore, execute the copying function of the setup of adaptive filter (SV.Pr2F) to the 1st notch frequency
(SV.Pr1D), or set up SV.Pr1D (1st notch frequency) manually by using the table below, then invalidate this
filter.