[Adjustment]
Adjustment
Setup of parameter, Pr21
Press .
Press .
Match to the parameter No. 
to be set up with . (Here match to Pr21.)
Press .
Change the setup with .
Press .
Setup of parameter, Pr22
Match to Pr22 with .
Press .
Numeral increases with , 
and decreases with . 
Press .
(default values)
Writing to EEPROM 
Press .
Press .
Bars increase as the right fig. shows 
by keep pressing (approx. 5sec).
Writing starts (temporary display).
Finish
Writing completes Writing error
occurs
Insert the console connector to 
CN X6 of the driver, then turn 
on the driver power.
Press to return to , after writing finishes.
SELECTION display
3) Set up SV.Pr22 (Machine stiffness at auto tuning) to 0 or smaller value.
4) Turn to Servo-ON to run the machine normally.
5) Gradually increase SV.Pr22 (Machine stiffness at auto tuning) when you want to obtain a better response.
Lower the value (0 to 3) when you experience abnormal noise or oscillation.